Performances and limitations of the HRMS method for dioxins, furans and dioxin-like PCBs analysis in animal feedingstuffs Part II: Does it comply with the European pro-active approach?

被引:6
作者
Eppe, G
Maghuin-Rogister, G
De Pauw, E
机构
[1] Univ Liege, Dept Physicochem, CART, Mass Spectrometry Lab, B-4000 Liege, Belgium
[2] Univ Liege, CART, Lab Anal Foodstuffs & Anim Origin, B-4000 Liege, Belgium
关键词
dioxins; furans; dioxin-like PCBs; HRMS; detection and quantification limits; compliance and non-compliance; measurement uncertainty;
D O I
10.1016/j.aca.2004.06.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Based on the results obtained from the inter-laboratory study in Part 1, different approaches for detection and quantification limits are evaluated and discussed. An overview of the most commonly used concepts and terminologies in analytical chemistry is presented with the aim of establishing a link between them. Whatever the method used by laboratories for detection limit assessment, the median LOD value reported for the less chlorinated PCDD/Fs (i.e. 0.02 ng/kg) is in good agreement with the values recalculated using the inter-laboratory data. For LOQ the Eurachem approach based on a pre-established percentage of repeatability RSD appears to be. suitable. The study shows that a pre-established RSDr of 20% is recommended in order to achieve an acceptable LOQ of 0.05 ng/kg per congener. The 20% value seems to be sufficiently low to act tolerable RSD close to maximum limits. Furthermore, the repeatability and the reproducibility standard deviation against parts-per-trillion congener levels has been modeled by inverse first order functions. This congener precision model provides an interesting tool to subsequently assess the performances of the method in TEQ close to regulatory limits. Finally, the paper discusses two different ways of reporting and interpreting the results to assess compliance against statutory limits. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:243 / 253
页数:11
相关论文
共 6 条
[1]   Detection and quantification limits: origins and historical overview [J].
Currie, LA .
ANALYTICA CHIMICA ACTA, 1999, 391 (02) :127-134
[2]   NOMENCLATURE IN EVALUATION OF ANALYTICAL METHODS INCLUDING DETECTION AND QUANTIFICATION CAPABILITIES (IUPAC RECOMMENDATIONS 1995) [J].
CURRIE, LA .
PURE AND APPLIED CHEMISTRY, 1995, 67 (10) :1699-1723
[3]   Background contamination by coplanar polychlorinated biphenyls (PCBs) in trace level high resolution gas chromatography high resolution mass spectrometry (HRGC/HRMS) analytical procedures [J].
Ferrario, J ;
Byrne, C ;
Dupuy, AE .
CHEMOSPHERE, 1997, 34 (11) :2451-2465
[4]   CORRELATION OF ENVIRONMENTAL OCCURRENCE OF POLYCHLORINATED DIBENZO-P-DIOXINS AND DIBENZOFURANS WITH POSSIBLE SOURCES [J].
HAGENMAIER, H ;
LINDIG, C ;
SHE, J .
CHEMOSPHERE, 1994, 29 (9-11) :2163-2174
[5]  
[No title captured]
[6]  
[No title captured]