A review of assigned protection factors of various types and classes of respiratory protective equipment with reference to their measured breathing resistances

被引:11
作者
Clayton, MP
Bancroft, B
Rajan, B
机构
[1] Hlth & Safety Lab, Sheffield S3 7HQ, S Yorkshire, England
[2] Hlth & Safety Execut, Div Technol, Bootle L20 3QZ, Merseyside, England
关键词
assigned protection factors; breathing apparatus; breathing resistance; respirators; respiratory protective equipment;
D O I
10.1093/annhyg/mef071
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 [公共卫生与预防医学]; 120402 [社会医学与卫生事业管理];
摘要
The British Standards Institution 'Guide to implementing an effective respiratory protective device programme' (BS 4275) lists assigned protection factors (APFs) for various types of respiratory protective equipment (RPE). The APFs were allocated either on the basis of available workplace studies data which met set criteria or on the basis of professional judgement that there is equivalence between its operation and that of a device for which an APF is derived from workplace data. However, in many cases no workplace study information exists to support this professional judgement. As an interim measure, pending information based on workplace measurements, the breathing resistance of a range of tight-fitting RPE from negative pressure filtering devices through to self-contained positive pressure breathing apparatus was measured at various breathing rates. The relative inhalation resistances were then compared on the assumption that similar breathing resistance performance is likely to give similar inward leakage on a facepiece and hence similar protection if all other factors, such as fit, etc., are equal. This work indicates that for most devices the allocation of APFs by analogy to other devices seems to be acceptable. However, there appears to be no justification for the allocation of an APF value of 100 to continuous flow compressed air line breathing apparatus. It is recommended that it should be lowered to 40 until there is valid workplace study data to support the current APF of 100. The work provides an informative insight into the relative performance of devices.
引用
收藏
页码:537 / 547
页数:11
相关论文
共 16 条
[1]
*BSI, 1997, BS4275 GUID IMPL EFF
[2]
Campbell D, 1984, J INT SOC RESPIR PRO, V2, P198
[3]
*EUR COMM STAND, 1998, RESPIRATORY PROTECTI
[4]
*EUR COMM STAND, 1999, RESPIRATORY PROTEC 1
[5]
*EUR COMM STAND, 1994, RESP PROT DEV COMPR
[6]
*EUR COMM STAND, 1994, RESPIRATORY PROTECTI
[7]
RESPIRATOR PROTECTION FACTORS .2. PROTECTION FACTORS OF SUPPLIED-AIR RESPIRATORS [J].
HACK, AL ;
BRADLEY, OD ;
TRUJILLO, A .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1980, 41 (05) :376-381
[8]
JOHNSTON AR, 1992, AM IND HYG ASSOC J, V53, P705, DOI 10.1202/0002-8894(1992)053<0705:RORPTI>2.0.CO
[9]
2
[10]
EVALUATION OF NEW IN-FACEPIECE SAMPLING PROCEDURES FOR FULL AND HALF FACEPIECES [J].
MYERS, WR ;
HORNUNG, RW .
ANNALS OF OCCUPATIONAL HYGIENE, 1993, 37 (02) :151-166