Analytical methodology in quantitative digital subtraction radiography: Analyses of the aluminum reference wedge

被引:16
作者
Allen, KM
Hausmann, E
机构
[1] Department of Oral Biology, State University of New York, Buffalo, NY
[2] Department of Oral Biology, SUNY, Squire Hall, Buffalo
关键词
alveolar bone loss radiography; radiography; dental; subtraction; bone density; radiographic image interpretation; computer-assisted;
D O I
10.1902/jop.1996.67.12.1317
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AN ALUMINUM WEDGE CAN BE USED TO QUANTIFY volumetric change in crestal alveolar bone which has been identified through subtraction radiography. This study compares two methods for using an aluminum wedge for this purpose: 1) the aluminum wedge is present in both radiographs and used to determine the aluminum equivalent bone density present in the region of change for each radiograph; and 2) the aluminum wedge is present in only one radiograph and the difference image of the wedge in the subtraction image is used to calculate the aluminum equivalent change in bone density. Pairs of standardized x-rays were taken with synthetic bone chips of known weights placed when the second x-ray was taken. The volumetric change produced by the bone chips was calculated by the two methods. The relationship of the calculated volumes to the chip weights had a higher r(2) value (P < 0.05) for the two-wedge method than for the one-wedge method. The two-wedge method is recommended for volumetric quantification of alveolar bone change. The influence of the clarity of the aluminum wedge image in the x-ray pairs was also examined in this study and found to be significant. Attention must be given to factors which affect the aluminum wedge image characteristics to achieve optimal results.
引用
收藏
页码:1317 / 1321
页数:5
相关论文
共 13 条
[1]  
CURRY TS, 1984, CHRISTENSENS INTRO P, P290
[2]   A DIGITAL SUBTRACTION TECHNIQUE FOR DENTAL RADIOGRAPHY [J].
GRONDAHL, HG ;
GRONDAHL, K ;
WEBBER, RL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1983, 55 (01) :96-102
[3]   STUDIES ON THE ANGULAR REPRODUCIBILITY OF POSITIONING PATIENTS ADJACENT TO AN X-RAY TUBE .2. A NEW ELECTRONICALLY GUIDED, FORCE-SENSITIVE SENSOR-BASED ALIGNMENT SYSTEM [J].
HAUSMANN, E ;
KUTLUBAY, ME ;
ODROBINA, D ;
ALLEN, KM ;
LOZA, J ;
ORTMAN, L ;
WOBSCHAL, D .
JOURNAL OF PERIODONTAL RESEARCH, 1995, 30 (04) :294-297
[4]   A CONTEMPORARY PERSPECTIVE ON TECHNIQUES FOR THE CLINICAL-ASSESSMENT OF ALVEOLAR BONE [J].
HAUSMANN, E .
JOURNAL OF PERIODONTOLOGY, 1990, 61 (03) :149-156
[5]   Validation of quantitative digital subtraction radiography using the electronically guided alignment device/impression technique [J].
Hausmann, E ;
Allen, K ;
Loza, J ;
Buchanan, W ;
Cavanaugh, PF .
JOURNAL OF PERIODONTOLOGY, 1996, 67 (09) :895-899
[6]  
Jeffcoat M K, 1992, Clin Oral Implants Res, V3, P22, DOI 10.1034/j.1600-0501.1992.030104.x
[7]  
Jeffcoat M K, 1993, Adv Dent Res, V7, P196
[8]   RADIOGRAPHIC DIAGNOSIS IN PERIODONTICS [J].
JEFFCOAT, MK ;
WANG, IC ;
REDDY, MS .
PERIODONTOLOGY 2000, 1995, 7 :54-68
[9]   A COMPARISON OF TOPICAL KETOROLAC, SYSTEMIC FLURBIPROFEN, AND PLACEBO FOR THE INHIBITION OF BONE LOSS IN ADULT PERIODONTITIS [J].
JEFFCOAT, MK ;
REDDY, MS ;
HAIGH, S ;
BUCHANAN, W ;
DOYLE, MJ ;
MEREDITH, MP ;
NELSON, SL ;
GOODALE, MB ;
WEHMEYER, KR .
JOURNAL OF PERIODONTOLOGY, 1995, 66 (05) :329-338
[10]   VOLUMETRY OF LOCALIZED BONE-LESIONS BY SUBTRACTION RADIOGRAPHY [J].
RUTTIMANN, UE ;
WEBBER, RL .
JOURNAL OF PERIODONTAL RESEARCH, 1987, 22 (03) :215-216