An introduction to bismuth film electrode for use in cathodic electrochemical detection

被引:161
作者
Hutton, EA
Ogorevc, B
Hocevar, SB
Weldon, F
Smyth, MR
Wang, J
机构
[1] Natl Inst Chem, Analyt Chem Lab, SI-1001 Ljubljana, Slovenia
[2] Dublin City Univ, Sch Chem Sci, Natl Ctr Sensor Res, Dublin 9, Ireland
[3] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
关键词
bismuth film electrode; electrochemical detection; voltammetry; amperometry; cathodic reduction; organic electroanalysis;
D O I
10.1016/S1388-2481(01)00240-5
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A new electrode surface design, the bismuth film electrode (BiFE), is presented as a promising alternative to mercury and other solid electrodes for direct cathodic electrochemical detection of organic compounds. The preparation of the BiFE, involving an ex situ electroplating of metallic bismuth onto a glassy carbon (GC) substrate electrode, was optimised. The useful negative potential windows of the BiFE in the pH range 1 (-0.2 to -0.8 V vs Ag/AgCl) to 10 (-0.2 to -1.5 V) were determined. The reproducibility of measuring 2-nitrophenol as a model compound (relative standard deviation, r.s.d., n=10) was found to be 0.5% at the same BiFE, and 1.0% at successive newly prepared BiFEs. No polishing or any other pre-treatment of the substrate GC surface was required prior to re-plating of a new Bi film. The BiFE showed similar or even favourable voltammetric behaviour when compared to mercury and bare GC electrodes, and was successfully tested for amperometric detection under hydrodynamic conditions. The results revealed that BiFE is an attractive new non-mercury metallic electrode particularly suitable for cathodic electrochemical detection in flow analytical systems. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:707 / 711
页数:5
相关论文
共 29 条
[1]   DETERMINATION OF 2-NITROPHENOL, 4-NITROPHENOL, 2-METHOXY-5-NITROPHENOL, AND 2,4-DINITROPHENOL BY DIFFERENTIAL-PULSE VOLTAMMETRY AND ADSORPTIVE STRIPPING VOLTAMMETRY [J].
BAREK, J ;
EBERTOVA, H ;
MEJSTRIK, V ;
ZIMA, J .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1994, 59 (08) :1761-1771
[2]   POLAROGRAPHIC, VOLTAMMETRIC, AND HPLC-EC OF PHARMACEUTICALLY RELEVANT CYCLIC-COMPOUNDS [J].
BERSIER, PM ;
BERSIER, J .
ELECTROANALYSIS, 1994, 6 (03) :171-191
[3]   Comparison of the voltammetric behavior of metronidazole at a DNA-modified glassy carbon electrode, a mercury thin film electrode and a glassy carbon electrode [J].
Brett, AMO ;
Serrano, SHP ;
Gutz, IGR ;
LaScalea, MA .
ELECTROANALYSIS, 1997, 9 (02) :110-114
[4]   BATCH SQUARE-WAVE VOLTAMMETRIC AND FLOW-INJECTION AMPEROMETRIC DETERMINATION OF TRACE AMOUNTS OF BROMOFENOXIM [J].
CAI, XH ;
OGOREVC, B ;
BENFENATI, E ;
KALCHER, K ;
NOVIC, M ;
GRABEC, I .
ANALYTICA CHIMICA ACTA, 1995, 310 (01) :153-160
[5]  
Chen XH, 1998, ELECTROANAL, V10, P695, DOI 10.1002/(SICI)1521-4109(199808)10:10<695::AID-ELAN695>3.0.CO
[6]  
2-7
[7]  
GALUS Z, 1996, LAB TECHNIQUES ELECT, pCH14
[8]  
GERHARTZ W, 1985, ULLMANS ENCY IND CHE, P187
[9]  
HUTTON EA, UNPUB
[10]   SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993 [J].
KALCHER, K ;
KAUFFMANN, JM ;
WANG, J ;
SVANCARA, I ;
VYTRAS, K ;
NEUHOLD, C ;
YANG, Z .
ELECTROANALYSIS, 1995, 7 (01) :5-22