Anterior cruciate ligament graft fixation - Initial comparison of patellar tendon and semitendinosus autografts in young fresh cadavers

被引:119
作者
Rowden, NJ
Sher, D
Rogers, GJ
Schindhelm, K
机构
[1] UNIV NEW S WALES,GRAD SCH BIOMED ENGN,SYDNEY,NSW 2052,AUSTRALIA
[2] PRINCE WALES HOSP,DEPT TRAUMAT & ORTHOPAED SURG,SYDNEY,NSW,AUSTRALIA
关键词
D O I
10.1177/036354659702500409
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The initial biomechanical properties of semitendinosus and patellar tendon autografts and their fixation strengths were investigated. Twenty fresh cadaveric knees from donors under 42 years of age were used in the study. After removing all soft tissues other than the anterior cruciate ligament, we determined the ultimate tensile strength (2195 +/- 427 N) and stiffness (306 +/- 80 N/mm) of the anterior cruciate ligament in nine knees. In six knees, anterior cruciate ligaments were reconstructed using an autologous patellar tendon graft with proximal and distal interference fit screws; this resulted in an ultimate tensile strength of 416 +/- 66 N. Five knees were reconstructed with quadruple-stranded (double-looped) semitendinosus tendons fixed proximally by a titanium button and braided tape and distally by tibial post screw. This resulted in an ultimate tensile strength of 612 +/- 73 N, which was significantly higher than the strength in the patellar tendon group. Graft stiffness did not differ between the groups and was 47 +/- 19 N/mm (N = 11). This study demonstrates that the reconstructed knees had only 20% to 30% of the ultimate tensile strength of the normal anterior cruciate ligament. In summary, the semitendinosus reconstruction using a button for proximal fixation is, at the time of surgery, approximately 50% stronger than patellar tendon reconstructions with similar stiffness.
引用
收藏
页码:472 / 478
页数:7
相关论文
共 29 条
[1]   PATELLAR TENDON VERSUS DOUBLED SEMITENDINOSUS AND GRACILIS TENDONS FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
AGLIETTI, P ;
BUZZI, R ;
ZACCHEROTTI, G ;
DEBIASE, P .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (02) :211-218
[2]   THE STRENGTH OF ARTIFICIAL LIGAMENT ANCHORAGES - A COMPARATIVE EXPERIMENTAL-STUDY [J].
AMIS, AA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03) :397-403
[3]  
Bonatus T J, 1991, Orthop Rev, V20, P770
[4]  
BROWN CH, 1993, CLIN SPORT MED, V12, P723
[5]   THE BIOMECHANICS OF INTERFERENCE SCREW FIXATION OF PATELLAR TENDON ANTERIOR CRUCIATE LIGAMENT GRAFTS [J].
BROWN, CH ;
HECKER, AT ;
HIPP, JA ;
MYERS, ER ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) :880-886
[6]  
BUTLER DL, 1985, CLIN ORTHOP RELAT R, V196, P26
[7]  
CALLAWAY G, 1994, ORTHOP T, V18, P1017
[8]  
CLANCY WG, 1985, ORTHOP CLIN N AM, V16, P181
[9]  
Conover W, 1980, PRACTICAL NONPARAMET, P229
[10]  
DISTEFANO V, 1993, CLIN SPORT MED, V12, P1