Fresh-frozen vs. embalmed bone: is it possible to use formalin-fixed human bone for biomechanical experiments on implants?

被引:28
作者
Comert, Ayhan [1 ]
Kokat, Ali Murat [2 ]
Akkocaoglu, Murat [3 ,4 ]
Tekdemir, Ibrahim [1 ]
Akca, Kivanc [5 ]
Cehreli, Murat Cavit [6 ]
机构
[1] Ankara Univ, Fac Med, Dept Anat, TR-06100 Ankara, Turkey
[2] Yeditepe Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey
[3] Guler Oral & Dent Hlth Polyclin, Sect Oral Surg, Ankara, Turkey
[4] Dept Oral Surg, Ankara, Turkey
[5] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[6] CosmORAL Oral & Dent Hlth Polyclin, Sect Prosthodont, Ankara, Turkey
关键词
bone; formalin; resonance frequency analysis; screw implant; torque; RESONANCE FREQUENCY-ANALYSIS; FORMALDEHYDE FIXATION; IN-VITRO; STABILITY; PRESERVATION; LIGAMENTS; DENSITY; MODEL; SPINE;
D O I
10.1111/j.1600-0501.2008.01682.x
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Purpose: As formalin is an extremely reactive electrophilic chemical that reacts with tissues, the purpose of this study was to explore whether formalin fixation could potentially alter the mechanical properties of bone tissue and have an effect on the primary stability measurements of implants. Material and methods: empty set 3.3 x 8 mm, empty set 4.1 x 8 mm, and empty set 4.8 x 8 mm implants were placed on sockets prepared into the anterior surface of the radius of two fresh-frozen human cadavers. The insertion torque of each implant was quantified using a strain-gauged torque-wrench connected to a data acquisition system at a sample rate of 10 KHz, and resonance frequency analysis measurements were also undertaken for each implant. The cadavers were then subjected to embalment with 10% formalin for 3 months, and the same experiments were undertaken on the contra lateral radius of the cadavers. Results: The insertion torques before and after chemical fixation were similar for empty set 3.3 mm (P > 0.05), and higher values were obtained for empty set 4.1 mm and empty set 4.8 mm implants after chemical fixation (P < 0.05). The resonance frequency analysis values before and after chemical fixation were similar for all implants (P < 0.05). Conclusions: Implants have higher insertion torque values in formalin-fixed bone than fresh-frozen human bone, but similar implant stability quotients in both cases. The insertion torque technique can detect the difference between formalin-fixed and fresh-frozen human bone, but resonance frequency analysis cannot.
引用
收藏
页码:521 / 525
页数:5
相关论文
共 26 条
[1]
The changes in crosslink contents in tissues after formalin fixation [J].
Abe, M ;
Takahashi, M ;
Horiuchi, K ;
Nagano, A .
ANALYTICAL BIOCHEMISTRY, 2003, 318 (01) :118-123
[2]
Implant design and intraosseous stability of immediately placed implants: a human cadaver study [J].
Akkocaoglu, M ;
Uysal, S ;
Tekdemir, I ;
Akca, K ;
Cehreli, MC .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (02) :202-209
[3]
Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model [J].
Al-Nawas, B. ;
Groetz, K. A. ;
Goetz, H. ;
Duschner, H. ;
Wagner, W. .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (01) :1-8
[4]
Practical light embalming technique for use in the surgical fresh tissue dissection laboratory [J].
Anderson, SD .
CLINICAL ANATOMY, 2006, 19 (01) :8-11
[5]
DENSITY OF FRESH AND EMBALMED HUMAN COMPACT AND CANCELLOUS BONE [J].
BLANTON, PL ;
BIGGS, NL .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1968, 29 (01) :39-&
[6]
HARD TISSUE BIOCHEMISTRY - A COMPARISON OF FRESH-FROZEN AND FORMALIN-FIXED TISSUE SAMPLES [J].
BOSKEY, AL ;
COHEN, ML ;
BULLOUGH, PG .
CALCIFIED TISSUE INTERNATIONAL, 1982, 34 (04) :328-331
[7]
BRANEMARK R, 1996, THESIS U GOTEBORG
[8]
Cannizzaro G, 2007, INT J ORAL MAX IMPL, V22, P280
[9]
THE COLLAGEN FIBRIL - A MODEL SYSTEM FOR STUDYING THE STAINING AND FIXATION OF A PROTEIN [J].
CHAPMAN, JA ;
TZAPHLIDOU, M ;
MEEK, KM ;
KADLER, KE .
ELECTRON MICROSCOPY REVIEWS, 1990, 3 (01) :143-182
[10]
COWIN SC, 2001, BONE MECH HDB, V20, P9