Blood pressure control by home monitoring: meta-analysis of randomised trials

被引:347
作者
Cappuccio, FP [1 ]
Kerry, SM
Forbes, L
Donald, A
机构
[1] St George Hosp, Sch Med, Dept Community Hlth Sci, London SW17 0RE, England
[2] Bazian Ltd, London N1 1QP, England
来源
BMJ-BRITISH MEDICAL JOURNAL | 2004年 / 329卷 / 7458期
关键词
D O I
10.1136/bmj.38121.684410.AE
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To determine the effect of home blood pressure monitoring on blood pressure levels and proportion achieving targets in people with essential hypertension. Design Meta-analysis of 18 randomised controlled trials. Participants 1359 people with essential hypertension allocated to home blood pressure monitoring and 1355 allocated to the "control" group seen in the healthcare system for 2-36 months. Main outcome measures Differences in systolic (n = 13 studies), diastolic (n = 16), or mean (n = 3) blood pressures, and proportion of patients achieving targets (n = 6), between intervention and control groups. Results Systolic blood pressure was lower in people with hypertension who had home blood pressure monitoring than in those who had standard blood pressure monitoring in the healthcare system (standardised mean difference 4.2 (95% confidence interval 1.5 to 6.9) mm Hg), diastolic blood pressure was lower by 2.4 (1.2 to 3.5) nun Hg, and mean blood pressure was lower by 4.4 (2.0 to 6.8) mm Hg. The relative risk of blood pressure above predetermined targets was lower in people with home blood pressure monitoring (risk ratio 0.90, 0.80 to 1.00). When publication bias was allowed for, the differences were attenuated: 2.2 (-0.9 to 5.3) mm Hg for systolic blood pressure and 1.9 (0.6 to 3.2) rum Hg for diastolic blood pressure. Conclusions Blood pressure control in people with hypertension (assessed in the clinic) and the proportion achieving targets are increased when home blood pressure monitoring is used compared with standard blood pressure monitoring in the healthcare system. The reasons for this are not clear. The difference in blood pressure control between the two methods is small but likely to contribute to an important reduction in vascular complications in the hypertensive population.
引用
收藏
页码:145 / 148A
页数:5
相关论文
共 41 条
[1]   Effects of home telemonitoring and community-based monitoring on blood pressure control in urban African Americans: A pilot study [J].
Artinian, NT ;
Washington, OGM ;
Templin, TN .
HEART & LUNG, 2001, 30 (03) :191-199
[2]  
Aylett M, 1999, BRIT J GEN PRACT, V49, P725
[3]   Antihypertensive drug treatment: A comparison of usual care with self blood pressure measurement [J].
Bailey, B ;
Carney, SL ;
Gillies, AAH ;
Smith, AJ .
JOURNAL OF HUMAN HYPERTENSION, 1999, 13 (02) :147-150
[4]   A COMPARISON OF COMPLIANCE TECHNIQUES ON THE CONTROL OF HIGH BLOOD-PRESSURE [J].
BINSTOCK, ML ;
FRANKLIN, KL .
AMERICAN JOURNAL OF HYPERTENSION, 1988, 1 (03) :S192-S194
[5]   Management of hypertension in the elderly using home blood pressures [J].
Broege, PA ;
James, GD ;
Pickering, TG .
BLOOD PRESSURE MONITORING, 2001, 6 (03) :139-144
[6]  
Brueren MM, 1998, BRIT J GEN PRACT, V48, P1585
[7]   EFFECTS OF SELF-MONITORING BY PATIENTS ON CONTROL OF HYPERTENSION [J].
CARNAHAN, JE ;
NUGENT, CA .
AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1975, 269 (01) :69-73
[8]   OBJECTIVE MEASUREMENT OF ANXIETY IN HYPERTENSIVE PREGNANT-WOMEN MANAGED IN HOSPITAL AND IN THE COMMUNITY [J].
CARTWRIGHT, W ;
DALTON, KJ ;
SWINDELLS, H ;
RUSHANT, S ;
MOONEY, P .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1992, 99 (03) :182-185
[9]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[10]   BLOOD-PRESSURE, STROKE, AND CORONARY HEART-DISEASE .2. SHORT-TERM REDUCTIONS IN BLOOD-PRESSURE - OVERVIEW OF RANDOMIZED DRUG TRIALS IN THEIR EPIDEMIOLOGIC CONTEXT [J].
COLLINS, R ;
PETO, R ;
MACMAHON, S ;
HEBERT, P ;
FIEBACH, NH ;
EBERLEIN, KA ;
GODWIN, J ;
QIZILBASH, N ;
TAYLOR, JO ;
HENNEKENS, CH .
LANCET, 1990, 335 (8693) :827-838