A Closed-Loop Control Strategy for Air Conditioning Loads to Participate in Demand Response

被引:33
作者
Hu, Xiaoqing [1 ]
Wang, Beibei [1 ]
Yang, Shengchun [2 ]
Short, Taylor [3 ]
Zhou, Lei [1 ]
机构
[1] Southeast Univ, Dept Elect Engn, Nanjing 210096, Jiangsu, Peoples R China
[2] China Elect Power Res Inst, Nanjing 210003, Peoples R China
[3] Univ Tennessee, Dept Elect Engn & Comp Sci, Knoxville, TN 37996 USA
基金
中国国家自然科学基金;
关键词
demand response; thermostatically controlled loads; air conditioning; closed-loop control; peak load shifting; THERMOSTATICALLY CONTROLLED LOADS; CONVERGENCE ANALYSIS; POWER; POPULATIONS;
D O I
10.3390/en8088650
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
080707 [能源环境工程]; 082001 [油气井工程];
摘要
Thermostatically controlled loads (TCLs), such as air conditioners (ACs), are important demand response resourcesthey have a certain heat storage capacity. A change in the operating status of an air conditioner in a small range will not noticeably affect the users' comfort level. Load control of TCLs is considered to be equivalent to a power plant of the same capacity in effect, and it can significantly reduce the system pressure to peak load shift. The thermodynamic model of air conditioning can be used to study the aggregate power of a number of ACs that respond to the step signal of a temperature set point. This paper analyzes the influence of the parameters of each AC in the group to the indoor temperature and the total load, and derives a simplified control model based on the two order linear time invariant transfer function. Then, the stability of the model and designs its Proportional-Integral-Differential (PID) controller based on the particle swarm optimization (PSO) algorithm is also studied. The case study presented in this paper simulates both scenarios of constant ambient temperature and changing ambient temperature to verify the proposed transfer function model and control strategy can closely track the reference peak load shifting curves. The study also demonstrates minimal changes in the indoor temperature and the users' comfort level.
引用
收藏
页码:8650 / 8681
页数:32
相关论文
共 30 条
[1]
[Anonymous], INT J SYST SCI
[2]
Bode J., 2012, MEASURING SHORT TERM
[3]
Achieving Controllability of Electric Loads [J].
Callaway, Duncan S. ;
Hiskens, Ian A. .
PROCEEDINGS OF THE IEEE, 2011, 99 (01) :184-199
[4]
Tapping the energy storage potential in electric loads to deliver load following and regulation, with application to wind energy [J].
Callaway, Duncan S. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (05) :1389-1400
[5]
A Dynamic Fuzzy Controller to Meet Thermal Comfort by Using Neural Network Forecasted Parameters as the Input [J].
Collotta, Mario ;
Messineo, Antonio ;
Nicolosi, Giuseppina ;
Pau, Giovanni .
ENERGIES, 2014, 7 (08) :4727-4756
[6]
Demand Response Programs Design and Use Considering Intensive Penetration of Distributed Generation [J].
Faria, Pedro ;
Vale, Zita ;
Baptista, Jose .
ENERGIES, 2015, 8 (06) :6230-6246
[7]
IDENTIFICATION OF STOCHASTIC ELECTRIC LOAD MODELS FROM PHYSICAL DATA [J].
GALIANA, FD ;
HANDSCHIN, E ;
FIECHTER, AR .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) :887-893
[8]
Goodwin G.C., 2000, CONTROL SYSTEM DESIG, V1st
[9]
Stochastic convergence analysis and parameter selection of the standard particle swarm optimization algorithm [J].
Jiang, M. ;
Luo, Y. P. ;
Yang, S. Y. .
INFORMATION PROCESSING LETTERS, 2007, 102 (01) :8-16