Weights of individual cusps in operatively-excised congenitally bicuspid stenotic-aortic valves

被引:8
作者
Roberts, WC
Ko, JM
机构
[1] Baylor Univ, Med Ctr, Baylor Heart & Vasc Inst, Dallas, TX 75246 USA
[2] Baylor Univ, Med Ctr, Dept Pathol, Dallas, TX 75246 USA
[3] Baylor Univ, Med Ctr, Dept Med, Dallas, TX 75246 USA
关键词
D O I
10.1016/j.amjcard.2004.05.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We weighed each cusp separately in 200 operatively excised stenotic congenitally bicuspid aortic valves. It was found in 152 patients (76%) that the cusps differed (by > 0.2 g) in weight and in 48 patients (24%) that the cusps were of similar (a less than or equal to 0.2 g difference) weights. In 161 of the 200 patients (80%), raphes were present in 1 cusp; the raphe and nonraphe cusps differed in weight in 120 patients (74%), with the raphe cusps being larger in 89 patients (74%), and were of similar weights in 41 patients (26%). Of the 39 patients with raphes in neither cusp, 32 cusps (82%) differed in weight and 7 (18%) were of similar weights. The weight of each cusp differed more as the total valve weights increased. (C) 2004 by Excerpta Medica, Inc.