Discrepant analysis: A biased and an unscientific method for estimating test sensitivity and specificity

被引:60
作者
Hadgu, A [1 ]
机构
[1] Ctr Dis Control & Prevent, Div STD Prevent, Atlanta, GA 30333 USA
关键词
discrepant analysis; sensitivity; specificity; DNA-amplification tests; Chlamydia trachomatis;
D O I
10.1016/S0895-4356(99)00101-8
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Discrepant analysis is a widely used technique for estimating test performance indices (sensitivity, specificity, etc.) of DNA-amplification tests for detecting infectious diseases. It has recently been claimed that the discrepant analysis-based estimates of specificity are typically less biased than those based on culture and that the discrepant analysis-based specificity shows little appreciable bias. In this article, I show that those conclusions are incorrect. Using a typical example from the published literature, I show that the discrepant analysis-based estimates of sensitivity and specificity can generate a significant and clinically important overestimation of the true sensitivity and specificity values. Moreover, I demonstrate that the concept of discrepant analysis is profoundly flawed and unscientific. It violates a fundamental principle of diagnostic testing-the principle that the new test should not be used to determine the true disease status. Thus, the major problem with discrepant analysis is not only that it is biased but that it is unscientific. Therefore, discrepant analysis should not be adopted for the evaluation of any diagnostic or screening test. Published by Elsevier Science Inc.
引用
收藏
页码:1231 / 1237
页数:7
相关论文
共 22 条
[1]   DETECTION OF CHLAMYDIA-TRACHOMATIS IN URINE SPECIMENS FROM WOMEN BY LIGASE CHAIN-REACTION [J].
BASSIRI, M ;
HU, HY ;
DOMEIKA, MA ;
BURCZAK, J ;
SVENSSON, LO ;
LEE, HH ;
MARDH, PA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (04) :898-900
[2]   Detection of Chlamydia trachomatis and Neisseria gonorrhoeae by ligase chain reaction-based assays with clinical specimens from various sites: Implications for diagnostic testing and screening [J].
Buimer, M ;
VanDoornum, GJJ ;
Ching, S ;
Peerbooms, PGH ;
Plier, PK ;
Ram, D ;
Lee, HH .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (10) :2395-2400
[3]  
Chernesky M, 1998, STAT MED, V17, P1064, DOI 10.1002/(SICI)1097-0258(19980515)17:9<1064::AID-SIM839>3.0.CO
[4]  
2-G
[5]   DIAGNOSIS OF CHLAMYDIA-TRACHOMATIS INFECTIONS IN MEN AND WOMEN BY TESTING FIRST-VOID URINE BY LIGASE CHAIN-REACTION [J].
CHERNESKY, MA ;
JANG, D ;
LEE, H ;
BURCZAK, JD ;
HU, H ;
SELLORS, J ;
TOMAZICALLEN, SJ ;
MAHONY, JB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (11) :2682-2685
[6]  
DEBARBEYRAC B, 1995, GENITOURIN MED, V71, P382
[7]   Evaluation of bias in diagnostic-test sensitivity and specificity estimates computed by discrepant analysis [J].
Green, TA ;
Black, CM ;
Johnson, RE .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (02) :375-381
[8]  
Hadgu A, 1997, STAT MED, V16, P1391, DOI 10.1002/(SICI)1097-0258(19970630)16:12<1391::AID-SIM636>3.0.CO
[9]  
2-1
[10]   The discrepancy in discrepant analysis [J].
Hadgu, A .
LANCET, 1996, 348 (9027) :592-593