Assessing agreement between CD34 enumeration by flow cytometry and volumetric analysis

被引:4
作者
Gisselo, CG
Roer, O
Hoffmann, MH
Hansen, MB
Taaning, E
Johnsen, HE [1 ]
机构
[1] Univ Copenhagen, Herlev Hosp, Dept Haematol, Stem Cell Lab, DK-2730 Herlev, Denmark
[2] Univ Copenhagen, Herlev Hosp, Dept Clin Immunol, DK-2730 Herlev, Denmark
[3] Univ Copenhagen, Herlev Hosp, Dept Oncol, Clin Res Unit, DK-2730 Herlev, Denmark
关键词
CD34; enumeration; flow cytometry; volumetric analysis;
D O I
10.1038/sj/bmt/1703514
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Prior to replacement of an established method for CD34 enumeration by an alternative approach, evaluation of the agreement between the methods is essential. In this study, the comparison of two assays was evaluated according to the recommendation of Bland and Altman describing the agreement between two methods where the true value is not known. CD34 enumeration was performed on blood or leukapheresis product from 105 patients by flow cytometry (dual platform assay) and volumetric analysis (single platform assay). Both the flow cytometric and the volumetric analysis showed poor reproducibility for measures lower than approximately 9 CD34(+) cells/mm(3). For values higher than 29 CD34(+) cells/mm(3), evaluation of the agreement demonstrated a difference between the single and dual platform assay, where CD34 enumeration by the volumetric analysis demonstrated values 73-80% of the flow cytometric value. The difference between the two assays could be due to several technical pitfalls which are discussed.
引用
收藏
页码:699 / 703
页数:5
相关论文
共 14 条
[1]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Comparison of volumetric capillary cytometry with standard flow cytometry for routine enumeration of CD34+cells [J].
Cabezudo, E ;
Querol, S ;
Cancelas, JA ;
García, J .
TRANSFUSION, 1999, 39 (08) :864-872
[4]  
Gratama JW, 1998, CYTOMETRY, V34, P128, DOI 10.1002/(SICI)1097-0320(19980615)34:3<128::AID-CYTO3>3.0.CO
[5]  
2-D
[6]   Validation of the Nordic flow cytometry standard for CD34+ cell enumeration in blood and autografts:: Report from the third workshop [J].
Johnsen, HE ;
Baech, J ;
Nikolajsen, K .
JOURNAL OF HEMATOTHERAPY, 1999, 8 (01) :15-28
[7]  
Keeney M, 1998, CYTOMETRY, V34, P61, DOI 10.1002/(SICI)1097-0320(19980415)34:2<61::AID-CYTO1>3.3.CO
[8]  
2-6
[9]   Evaluation of mobilized CD34+ cell counts to guide timing and yield of large-scale collection by leukapheresis [J].
Knudsen, LM ;
Gaarsdal, E ;
Jensen, L ;
Nikolaisen, K ;
Johnsen, HE .
JOURNAL OF HEMATOTHERAPY, 1998, 7 (01) :45-52
[10]   Enumeration of CD34+ hematopoietic progenitor cells in peripheral blood and leukapheresis products by microvolume fluorimetry: A comparison with flow cytometry [J].
Read, EJ ;
Kunitake, ST ;
Carter, CS ;
Chau, Q ;
Yu, MY ;
Klein, HG .
JOURNAL OF HEMATOTHERAPY, 1997, 6 (04) :291-301