Integrated microanalytical system for simultaneous voltammetric measurements of free metal ion concentrations in natural waters

被引:14
作者
Noel, Stephane
Tercier-Waeber, Mary-Lou
Lin, Lin
Buffle, Jacques
Guenat, Olivier
Koudelka-Hep, Milena
机构
[1] Univ Geneva, CABE, Dept Inorgan Analyt & Appl Chem, CH-1211 Geneva 4, Switzerland
[2] Univ Neuchatel, Inst Microtechnol, CH-2007 Neuchatel, Switzerland
关键词
metal speciation; free metal ions; microsensor array; microanalytical system; square wave voltammetry; environmental analysis; natural waters;
D O I
10.1002/elan.200503632
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A complexing gel integrated microelectrode (CLIME) for direct measurements of free metal ion concentrations in natural waters has been developed. It is prepared by the successive deposition of microlayers of a chelating resin, an antifouling agarose gel and Hg on a 100-interconnected Ir-based microelectrode array. The trace metals of interest are in a first step accumulated on the chelating resin in proportion to their free ion concentration in solution, then released in acidic solution and detected simultaneously by using square wave anodic stripping voltammetry (SWASV). The reliability of this sensor for the simultaneous measurement of copper, lead and cadmium has been studied by a series of replicate laboratory tests. The proportionality between the voltammetric peak current intensity and the free metal ion concentrations in solution has been demonstrated by using malonate as a model ligand. Finally, the CLIME sensor was applied to the Cu and Pb free concentration measurement in sea water samples and the results compared to the free metal ion concentrations measured using hollow fiber based permeation liquid membrane (HF-PLM) coupled to inductively coupled plasma mass spectrophotometer (ICP-MS). Comparable concentration values were found for both metals with both techniques allowing to validate the CLIME measurements in complex media.
引用
收藏
页码:2061 / 2069
页数:9
相关论文
共 23 条
[1]  
Bakker E, 2001, TRAC-TREND ANAL CHEM, V20, P11, DOI 10.1016/S0165-9936(00)00056-X
[2]   Gel-integrated microelectrode arrays for direct voltammetric measurements of heavy metals in natural waters and other complex media [J].
Belmont-Hébert, C ;
Tercier, ML ;
Buffle, J ;
Fiaccabrino, GC ;
de Rooij, NF ;
Koudelka-Hep, M .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2949-2956
[3]  
Buffle J., 2000, IUPAC SERIES ANAL PH, P407
[4]  
BUFFLE J, 2000, IUPAC SERIES ANAL PH, V6
[5]   Metal bioavailability to phytoplankton -: applicability of the biotic ligand model [J].
Campbell, PGC ;
Errécalde, O ;
Fortin, C ;
Hiriart-Baer, WR ;
Vigneault, B .
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY C-TOXICOLOGY & PHARMACOLOGY, 2002, 133 (1-2) :189-206
[6]   Stability constants of water-soluble and latex types of chelating polymers containing iminodiacetic acid with some transition-metal ions [J].
Chen, CY ;
Chen, CY .
EUROPEAN POLYMER JOURNAL, 2003, 39 (05) :991-1000
[7]   Size effects on diffusion processes within agarose gels [J].
Fatin-Rouge, N ;
Starchev, K ;
Buffle, J .
BIOPHYSICAL JOURNAL, 2004, 86 (05) :2710-2719
[8]  
FIACCABRINO GC, 2000, IUPAC SERIES ANAL PH, V6, P571
[9]   CURRENT MULTIPLIER FOR USE WITH ULTRAMICROELECTRODES [J].
HUANG, HJ ;
HE, P ;
FAULKNER, LR .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2889-2891
[10]  
Morel F.M.M., 1983, PRINCIPLES APPL AQUA