Design and validation of a wind tunnel system for odour sampling on liquid area sources

被引:34
作者
Capelli, L. [1 ]
Sironi, S. [1 ]
Del Rosso, R. [1 ]
Centola, P. [1 ]
机构
[1] Politecn Milan, Dept Chem Mat & Chem Engn Giulio Natta, Olfactometr Lab, I-20133 Milan, Italy
关键词
area sources; dynamic olfactometry; odour; sampling; wind tunnel; RATES;
D O I
10.2166/wst.2009.123
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study is to describe the methods adopted for the design and the experimental validation of a wind tunnel, a sampling system suitable for the collection of gaseous samples on passive area sources, which allows to simulate wind action on the surface to be monitored. The first step of the work was the study of the air velocity profiles. The second step of the work consisted in the validation of the sampling system. For this purpose, the odour concentration of some air samples collected by means of the wind tunnel was measured by dynamic olfactometry. The results of the air velocity measurements show that the wind tunnel design features enabled the achievement of a uniform and homogeneous air flow through the hood. Moreover, the laboratory tests showed a very good correspondence between the odour concentration values measured at the wind tunnel outlet and the odour concentration values predicted by the application of a specific volatilization model, based on the Prandtl boundary layer theory. The agreement between experimental and theoretical trends demonstrate that the studied wind tunnel represents a suitable sampling system for the simulation of specific odour emission rates from liquid area sources without outward flow.
引用
收藏
页码:1611 / 1620
页数:10
相关论文
共 14 条
[1]  
[Anonymous], [No title captured]
[2]  
[Anonymous], J AIR WASTE MANAGEME
[3]   THE DEVELOPMENT OF A SAMPLING SYSTEM FOR THE DETERMINATION OF ODOR EMISSION RATES FROM AREAL SURFACES .2. MATHEMATICAL-MODEL [J].
BLISS, PJ ;
JIANG, KY ;
SCHULZ, TJ .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1995, 45 (12) :989-994
[4]   Measurement of odour with focus on sampling techniques [J].
Bockreis, A ;
Steinberg, I .
WASTE MANAGEMENT, 2005, 25 (09) :859-863
[5]   A comparative and critical evaluation of odour assessment methods on a landfill site [J].
Capelli, Laura ;
Sironi, Selena ;
Del Rosso, Renato ;
Centola, Paolo ;
Il Grande, Massimiliano .
ATMOSPHERIC ENVIRONMENT, 2008, 42 (30) :7050-7058
[6]  
EN 13725, 2003, 13725 EN COM EUR NOR
[7]   Aerodynamic performance of a low-speed wind tunnel [J].
Frechen, FB ;
Frey, M ;
Wett, M ;
Löser, C .
WATER SCIENCE AND TECHNOLOGY, 2004, 50 (04) :57-64
[8]   Odour measurements for sewage treatment works [J].
Gostelow, P ;
Parsons, SA ;
Stuetz, RM .
WATER RESEARCH, 2001, 35 (03) :579-597
[9]  
JIANG J, 2001, ODOURS WASTEWATER TR, P98
[10]   Comparison study on portable wind tunnel system and isolation chamber for determination of VOCs from areal sources [J].
Jiang, KY ;
Kaye, R .