Comparison of a multiplex, bead-based fluorescent assay and immunofluorescence methods for the detection of ANA and ANCA autoantibodies in human serum

被引:51
作者
Nifli, Artemissia-Phoebe [1 ]
Notas, George [1 ]
Mamoulaki, Marilena [1 ]
Niniraki, Maria [1 ]
Ampartzaki, Vaso [1 ]
Theodoropoulos, Panayiotis A. [1 ]
Kopnitsky, Mark J. [1 ]
Castanas, Elias [1 ]
机构
[1] Univ Crete, Lab Expt Endocrinol, Sch Med, GR-71003 Iraklion, Greece
关键词
antinuclear antibodies (ANA); antineutroplil cytoplasmic antibodies (ANCA); extractable nuclear antigen (ENA) screen; multiplex bead-based fluorescent assay; autoimmune diseases;
D O I
10.1016/j.jim.2006.02.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
l Detection of antinuclear (ANA) and antineutrophil cytoplasmic (ANCA) antibodies is extensively used for establishing a diagnosis in patients with clinical features suggestive of autoimmune disorders. The most common methods for the identification of positive patients' sera for ANA or ANCA are indirect immunofluorescence (IIF) and ELISA-based procedures. Considerable Mort has been made in developing simpler automated assays for routine laboratory use. Recently a commercially available microsphere-based fluorescent assay has been introduced for the detection of ANA and ANCA. The aim of this Study was to compare this technology with routinely used IIF and ELISA procedures, in patients with a suggested autominutne disorder, A highly significant correlation between ELISA procedures for specific antibodies and the microsphere-based assays were obtained for both ANA and ANCA as well as for extractable nuclear antigens ELISA screening, indicating that Multiplex technology could replace individual ELISA tests for the measurement of specific autoantibodies. However, a low sensitivity for identifying HF-positive cases was obtained for both ANA (58-0%) and ANCA (59.1%), although there was a significant correlation between the assays. In conclusion. our data show that a microsphere-based fluorescent assay may be a valid platform for the simultaneous determination of circulating individual ANA and ANCA autoantibodies. Furthermore, multiplexing technology offers several advantages that will probably make it an attractive tool ill the future. Nevertheless, until further Studies are conducted that determine the clinical performance of the multiplex technology, the initial screening of patients for autoantibodies with IIF is still considered necessary. (c) 2006 Elsevier BY All rights reserved.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 36 条
[1]  
Buliard A, 2005, ANN BIOL CLIN-PARIS, V63, P51
[2]   Flow cytometric microsphere-based immunoassay:: Analysis of secreted ctytokines in whole-blood samples from asthmatics [J].
Camilla, C ;
Mély, L ;
Magnan, A ;
Casano, B ;
Prato, S ;
Debono, S ;
Montero, F ;
Defoort, JP ;
Martin, M ;
Fert, V .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2001, 8 (04) :776-784
[3]   Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay [J].
Carson, RT ;
Vignali, DAA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 227 (1-2) :41-52
[4]  
COREMANS IEM, 1993, CLIN EXP RHEUMATOL, V11, P255
[5]   Simultaneous detection of 15 human cytokines in a single sample of stimulated peripheral blood mononuclear cells [J].
de Jager, W ;
te Velthuis, H ;
Prakken, BJ ;
Kuis, W ;
Rijkers, GT .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (01) :133-139
[6]   Quantitative, multiplexed detection of bacterial pathogens:: DNA and protein applications of the Luminex LabMAP™ system [J].
Dunbar, SA ;
Vander Zee, CA ;
Oliver, KG ;
Karem, KL ;
Jacobson, JW .
JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 53 (02) :245-252
[7]  
Fritzler MJ, 2003, J RHEUMATOL, V30, P2374
[8]  
FROELICH CJ, 1990, J RHEUMATOL, V17, P192
[9]  
Galeazzi M, 1998, CLIN EXP RHEUMATOL, V16, P541
[10]  
Hoffman GS, 1998, ARTHRITIS RHEUM-US, V41, P1521, DOI 10.1002/1529-0131(199809)41:9<1521::AID-ART2>3.0.CO