Development of 6.6 kV-200 a DC reactor type superconducting fault current limiter

被引:13
作者
Lee, SJ [1 ]
Kang, HK
Bae, DK
Ahn, MC
Mun, T
Park, K
Lee, YJ
Ko, TK
机构
[1] Freecom Syst Co Ltd, Seoul 135010, South Korea
[2] Yonsei Univ, Dept Elect & Elect Engn, Seoul 120749, South Korea
[3] Seongnam Polytech Coll, Seongnam, Kyungeedo, South Korea
关键词
DC reactor; power converter; power system; superconducting fault current limiter (FCL); transformer;
D O I
10.1109/TASC.2004.830304
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As a part of the 21st Century Frontier R&D Program in Korea being performed from 2001, a DC Reactor type Superconducting Fault Current Limiter (SFCL) is being developed. The target of the first phase is to develop a 6.6 kV/200 A class 3-phase SFCL as a prototype for a 154 kV class. This prototype SFCL has a magnet wound with a high-T-c, superconducting wire (Bi-2223) operating at 65 K. The magnet uses solenoid bobbins with grooves for the tape wire. Its inductance is about 84 mH. An AC-DC power converter was made with Light Trigger Thyristor (LTT) having a phase controller. The maximum voltage is 7 kV. The DC reactor, which is cooled by sub-cooled nitrogen, uses a three phase transformer with dual tap for series connection with a power line. Through several experiments this SFCL shows current limiting performance about 50% of short circuit current at short run tests.
引用
收藏
页码:867 / 870
页数:4
相关论文
共 9 条
[1]   SUPERCONDUCTING MAGNETIC ENERGY-STORAGE [J].
HASSENZAHL, WV .
PROCEEDINGS OF THE IEEE, 1983, 71 (09) :1089-1098
[2]   Novel design and operational characteristics of inductive high-Tc superconducting fault current limiter [J].
Joo, M ;
Ko, TK .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) :1005-1008
[3]  
KANG H, 2002, KOR JAP JOINT WORKSH
[4]   Design and characteristic analysis of a rod type high-Tc superconducting fault current limiter through electromagnetic analysis [J].
Lee, C ;
Lee, S ;
Hyun, OB ;
Ko, TK .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) :2102-2105
[5]   The short circuit analysis of integrated three phase superconducting fault current limiter with two phase superconducting circuits [J].
Lee, S ;
Lee, ER ;
Lee, C ;
Choi, SJ ;
Ko, TK .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2002, 12 (01) :854-858
[6]   Stability analysis of a power system with superconducting fault current limiter installed [J].
Lee, S ;
Lee, C ;
Ko, TK ;
Hyun, O .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) :2098-2101
[7]   30-MJ SUPERCONDUCTING MAGNETIC ENERGY-STORAGE SYSTEM FOR ELECTRIC UTILITY TRANSMISSION STABILIZATION [J].
ROGERS, JD ;
SCHERMER, RI ;
MILLER, BL ;
HAUER, JF .
PROCEEDINGS OF THE IEEE, 1983, 71 (09) :1099-1107
[8]   66 kV-class high-TC superconducting fault current limiter magnet model coil experiment [J].
Yazawa, T ;
Koyama, H ;
Tasaki, K ;
Kuriyama, T ;
Nomura, S ;
Ohkuma, T ;
Hobara, N ;
Takahashi, Y ;
Inoue, K .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) :2040-2043
[9]  
YAZAWA T, INTER CRYO ENG, V19, P261