Recent developments in ion-trap mass spectrometry and related technologies

被引:18
作者
Brancia, Francesco L. [1 ]
机构
[1] Shimadzu Res Lab, Manchester M17 1GP, Lancs, England
关键词
digital ion trap; electron capture dissociation; electron transfer dissociation; linear ion trap; orbitrap; quadrupole ion trap;
D O I
10.1586/14789450.3.1.143
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Due to their versatility, quadrupole ion traps have become popular mass spectrometers in the growing field of proteomics. High sensitivity, user friendliness and low cost are the key features that have contributed to the success of the technology. However, mass measurement accuracy, resolution and mass range are still not comparable to the analytical performances obtained on other mass spectrometers. In the past 5 years, researchers have tried to overcome these drawbacks, focusing their attention on two different aspects of ion-trap mass spectrometry, development of novel types of ion traps and manipulation of the gas-phase ion chemistry, in order to obtain alternative techniques for tandem mass spectrometry analysis. In the field of trapping devices, improvements in instrumental design have led to the linear ion trap, digital ion trap and orbitrap. Activation methods based on electrons, chemically produced by an anion or from irradiation with an electron beam, have demonstrated their utility in providing complementary sequence information for improving confidence in protein identification.
引用
收藏
页码:143 / 151
页数:9
相关论文
共 56 条
[1]
Electron capture dissociation in a radio frequency ion trap [J].
Baba, T ;
Hashimoto, Y ;
Hasegawa, H ;
Hirabayashi, A ;
Waki, I .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :4263-4266
[2]
A new technique for unbiased external ion accumulation in a quadrupole two-dimensional ion trap for electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry [J].
Belov, ME ;
Nikolaev, EN ;
Alving, K ;
Smith, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (14) :1172-1180
[3]
Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization-fourier transform ion cyclotron resonance [J].
Belov, ME ;
Zhang, R ;
Strittmatter, EF ;
Prior, DC ;
Tang, K ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2003, 75 (16) :4195-4205
[4]
Effect of reverse scan on mass measurement accuracy in an ion trap mass spectrometer [J].
Brancia, FL ;
Giles, R ;
Ding, L .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (06) :702-704
[5]
Identification of bacteriophage MS2 coat protein from E-coli lysates via ion trap collisional activation of intact protein ions [J].
Cargile, BJ ;
McLuckey, SA ;
Stephenson, JL .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1277-1285
[6]
Protein kinase A phosphorylation characterized by tandem Fourier transform ion cyclotron resonance mass spectrometry [J].
Chalmers, MJ ;
Håkansson, K ;
Johnson, R ;
Smith, R ;
Shen, JW ;
Emmett, MR ;
Marshall, AG .
PROTEOMICS, 2004, 4 (04) :970-981
[7]
Liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometric characterization of protein kinase C phosphorylation [J].
Chalmers, MJ ;
Quinn, JP ;
Blakney, GT ;
Emmett, MR ;
Mischak, H ;
Gaskell, SJ ;
Marshall, AG .
JOURNAL OF PROTEOME RESEARCH, 2003, 2 (04) :373-382
[8]
Loss of charged versus neutral heme from gaseous holomyoglobin ions [J].
Chrisman, PA ;
Newton, KA ;
Reid, GE ;
Wells, JM ;
McLuckey, SA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (23) :2334-2340
[9]
The role of electron capture dissociation in biomolecular analysis [J].
Cooper, HJ ;
Håkansson, K ;
Marshall, AG .
MASS SPECTROMETRY REVIEWS, 2005, 24 (02) :201-222
[10]
Ion motion in the rectangular wave quadrupole field and digital operation mode of a quadrupole ion trap mass spectrometer [J].
Ding, L ;
Kumashiro, S .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (01) :3-8