Probing antigen-antibody binding processes by impedance measurements on ion-sensitive field-effect transistor devices and complementary surface plasmon resonance analyses: Development of cholera toxin sensors

被引:79
作者
Zayats, M [1 ]
Raitman, OA [1 ]
Chegel, VI [1 ]
Kharitonov, AB [1 ]
Willner, I [1 ]
机构
[1] Hebrew Univ Jerusalem, Inst Chem, IL-91904 Jerusalem, Israel
关键词
D O I
10.1021/ac020312f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Impedance measurements on ISFET devices are employed to develop new immunosensors. The analysis of the transconductance curves recorded at variable frequencies, upon the formation of antigen-antibody complexes on the ISFET devices, allows determination of the biomaterial film thicknesses. Complementary surface plasmon resonance measurements of analogous biosensor systems, using Au-coated glass slides as support, reveal similar film thicknesses of the biomaterials and comparable detection limits. A dinitrophenyl antigen layer is immobilized on the ISFET gate as a sensing interface for the anti-dinitrophenyl antibody (anti-DNP-Ab). The anti-DNP-Ab is analyzed with a sensitivity that corresponds to 0.1 mug mL(-1). The assembly of the biotinylated anti-anti-DNP-Ab and avidin layers on the base anti-DNP-Ab layer is characterized by impedance measurements. The development of an ISFET-based sensor for the cholera toxin is described. The anti-cholera toxin antibody is immobilized on the ISFET device. The association of the cholera toxin (CT) to the antibody is monitored by the impedance measurements. The detection limit for analyzing CT is 1.0 x 10(-11) M.
引用
收藏
页码:4763 / 4773
页数:11
相关论文
共 64 条
[1]   A quartz crystal microbalance assay for detection of antibodies against the recombinant African swine fever virus attachment protein p12 in swine serum [J].
Abad, JM ;
Pariente, F ;
Hernández, L ;
Lorenzo, E .
ANALYTICA CHIMICA ACTA, 1998, 368 (03) :183-189
[2]  
AIZAWA M, 1987, ELECTROCHEMICAL SENS, P269
[3]   Chronopotentiometry and Faradaic impedance spectroscopy as signal transduction methods for the biocatalytic precipitation of an insoluble product on electrode supports: routes for enzyme sensors, immunosensors and DNA sensors [J].
Alfonta, L ;
Bardea, A ;
Khersonsky, O ;
Katz, E ;
Willner, I .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :675-687
[4]   Membrane characterization of anion-selective CHEMFETs by impedance spectroscopy [J].
Antonisse, MMG ;
Snellink-Ruël, BHM ;
Lugtenberg, RJW ;
Engbersen, JFJ ;
van den Berg, A ;
Reinhoudt, DN .
ANALYTICAL CHEMISTRY, 2000, 72 (02) :343-348
[5]   PROPERTIES OF PVC BASED MEMBRANES USED IN ION-SELECTIVE ELECTRODES [J].
ARMSTRONG, RD ;
HORVAI, G .
ELECTROCHIMICA ACTA, 1990, 35 (01) :1-7
[6]   Probing the electrochemical deposition and/or desorption of self-assembled and electropolymerizable organic thin films by surface plasmon spectroscopy and atomic force microscopy [J].
Badia, A ;
Arnold, S ;
Scheumann, V ;
Zizlsperger, M ;
Mack, J ;
Jung, G ;
Knoll, W .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :145-165
[7]  
Bardea A, 2000, ELECTROANAL, V12, P1097, DOI 10.1002/1521-4109(200010)12:14<1097::AID-ELAN1097>3.3.CO
[8]  
2-O
[9]   ELECTROMAGNETIC-WAVES IN THE MOLECULAR LAYERS ADSORBED ON THE SURFACE OF A SOLID [J].
BARYAKHTAR, IV ;
DEMIDENKO, YV ;
KRIUCHENKO, SV ;
LOZOVSKII, VZ .
SURFACE SCIENCE, 1995, 323 (1-2) :142-150
[10]   Surface plasmon resonance spectroscopy: prospects of superstrate refractive index variation for separate extraction of molecular layer parameters [J].
Beketov, GV ;
Shirshov, YM ;
Shynkarenko, OV ;
Chegel, VI .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 48 (1-3) :432-438