Deconvolution: A novel signal processing approach for determining activation time from fractionated electrograms and detecting infarcted tissue

被引:28
作者
Ellis, WS
Eisenberg, SJ
Auslander, DM
Dae, MW
Zakhor, A
Lesh, MD
机构
[1] UNIV CALIF SAN FRANCISCO,CARDIOVASC RES INST,SAN FRANCISCO,CA 94143
[2] UNIV CALIF BERKELEY,BIOENGN GRAD GRP,BERKELEY,CA 94720
关键词
computers; electrophysiology; mapping; myocardial infarction; potentials;
D O I
10.1161/01.CIR.94.10.2633
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Two important signal processing applications in electrophysiology are activation mapping and characterization of the tissue substrate from which electrograms are recorded. We hypothesize that a novel signal-processing method that uses de convolution is more accurate than amplitude, derivative, and manual activation time estimates. We further hypothesize that deconvolution quantifies changes in morphology that detect electrograms recorded from regions of myocardial infarction. Methods and Results To determine the accuracy of activation time estimation, 600 unipolar electrograms were calculated with a detailed computer model using various degrees of coupling heterogeneity to model infarction. Local activation time was defined as the time of peak inward sodium current in the modeled myocyte closest to the electrode. Deconvolution, minimum derivative, and maximum amplitude were calculated. Two experienced electrophysiologists blinded to the computer-determined activation times marked their estimates of activation lime. F tests compared the variance of activation time estimation for each method. To evaluate the performance of deconvolution to detect infarction, 380 unipolar electrograms were recorded from 10 dogs with infarcts resulting from ligation of the left anterior descending coronary artery. The amplitude, duration, number of inflections, peak frequency, bandwidth, minimum derivative, and deconvolution were calculated. Metrics were compared by Mann-Whitney rank-sum tests, and receiver operating curves were plotted. Conclusions. Deconvolution estimated local activation time more accurately than the other metrics (P<.0001). Furthermore, the algorithm quantified changes in morphology (P<.0001) with superior performance, detecting electrograms recorded from regions of myocardial infarction. Thus, deconvolution, which incorporates a priori knowledge of electrogram morphology, shows promise to improve present clinical metrics.
引用
收藏
页码:2633 / 2640
页数:8
相关论文
共 28 条
[1]   RECONSTRUCTION OF ACTION POTENTIAL OF VENTRICULAR MYOCARDIAL FIBERS [J].
BEELER, GW ;
REUTER, H .
JOURNAL OF PHYSIOLOGY-LONDON, 1977, 268 (01) :177-210
[2]  
BERBARI EJ, 1992, J ELECTROCARDIOL, V24, P16
[3]   AN INTEGRATED SYSTEM FOR INTRAOPERATIVE CARDIAC ACTIVATION MAPPING [J].
BONNEAU, G ;
TREMBLAY, G ;
SAVARD, P ;
GUARDO, R ;
LEBLANC, AR ;
CARDINAL, R ;
PAGE, PL ;
NADEAU, RA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (06) :415-423
[4]   CLASSIFICATION OF HEART-TISSUE FROM BIPOLAR AND UNIPOLAR INTRAMURAL POTENTIALS [J].
CLAYDON, FJ ;
PILKINGTON, TC ;
IDEKER, RE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (07) :513-520
[5]  
Cohen L, 1995, Prentice Hall signal processing series
[6]   AN INTERACTIVE COMPUTER-SYSTEM FOR GUIDING THE SURGICAL-TREATMENT OF LIFE-THREATENING VENTRICULAR TACHYCARDIAS [J].
DEBAKKER, JMT ;
JANSE, MJ ;
VANCAPELLE, FJL ;
DURRER, D .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (04) :362-368
[7]  
DERENZO S, 1990, INTERFACING LAB APPR, P324
[8]  
Dimri V. P., 1992, DECONVOLUTION INVERS
[9]   FRACTIONATED ELECTROGRAMS FROM A COMPUTER-MODEL OF HETEROGENEOUSLY UNCOUPLED ANISOTROPIC VENTRICULAR MYOCARDIUM [J].
ELLIS, WS ;
AUSLANDER, DM ;
LESH, MD .
CIRCULATION, 1995, 92 (06) :1619-1626
[10]   DETECTION OF MOTOR UNIT ACTION-POTENTIALS WITH SURFACE ELECTRODES - INFLUENCE OF ELECTRODE SIZE AND SPACING [J].
FUGLEVAND, AJ ;
WINTER, DA ;
PATLA, AE ;
STASHUK, D .
BIOLOGICAL CYBERNETICS, 1992, 67 (02) :143-153