Cardiovascular stability during haemodialysis, haemofiltration and haemodiafiltration

被引:36
作者
Maggiore, Q [1 ]
Pizzarelli, F [1 ]
Dattolo, P [1 ]
Maggiore, U [1 ]
Cerrai, T [1 ]
机构
[1] Osped S Maria Annunziata, Dialysis & Nephrol Unit, I-50011 Florence, Italy
关键词
D O I
10.1093/oxfordjournals.ndt.a027967
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 [基础医学]; 1002 [临床医学]; 100602 [中西医结合临床];
摘要
Several comparative studies have claimed that procedures based substantially or exclusively on pressure-driven water-solute transport, such as haemodiafiltration or haemofiltration, afford better protection of the cardiovascular tolerance to fluid removal than conventional haemodialysis. During each depurative modality, several factors are set in motion that might impact, each in its own right, upon the haemodynamic response to fluid withdrawal. To explore the haemodynamic effect of each of them singularly, one needs to keep all other components unvaried. However, this is very difficult to accomplish. For instance, to confirm the alleged greater protection of cardiovascular stability by pure convection vs diffusion, one needs to keep unvaried all the other factors potentially affecting haemodynamic tolerance, i.e. the rate of body fluid removal, the membrane, the buffer, the blood temperature in the extracorporeal circuit, depuration efficiency, the sodium balance, the fluid sterility and so on. Such studies are still awaited. However, clinical trials published to date have not resolved the question of whether haemofiltration and haemodiafiltration provide a better haemodynamic tolerance to fluid removal. If we limit our consideration to controlled trials only, most prospective studies have adopted a cross-over design implemented on very small patient samples and for very short periods. Such an approach is liable to generate misleading results because the incidence of dialysis hypotension often fluctuates from time to time. Owing to such fluctuations, results can be strongly affected by the 'order effect' of the cross-over from one technique to the other. The negative results provided by parallel comparisons of procedures should be taken with caution because patients samples did not include a suitable proportion of unstable patients.
引用
收藏
页码:68 / 73
页数:6
相关论文
共 41 条
[1]
On-line predilution hemofiltration versus ultrapure high-flux hemodialysis: A multicenter prospective study in 23 patients [J].
Altieri, P ;
Sorba, GB ;
Bolasco, PG ;
Bostrom, M ;
Asproni, E ;
Ferrara, R ;
Bolasco, F ;
Cossu, M ;
Cadinu, F ;
Cabiddu, GF ;
Casu, D ;
Ganadu, M ;
Passaghe, M ;
Pinna, M .
BLOOD PURIFICATION, 1997, 15 (03) :169-181
[2]
SYMPATHETIC AND HEMODYNAMIC-RESPONSE TO VOLUME REMOVAL DURING DIFFERENT FORMS OF RENAL REPLACEMENT THERAPY [J].
BALDAMUS, CA ;
ERNST, W ;
FREI, U ;
KOCH, KM .
NEPHRON, 1982, 31 (04) :324-332
[3]
Bergstrom J, 1976, P EUR DIAL TRANSPLAN, V13, P293
[4]
COLI U, 1983, T AM SOC ART INT ORG, V29, P71
[5]
COLLINS AJ, 1985, KIDNEY INT S17, V28, pS18
[6]
The protective effect of cool dialysate is dependent on patients' predialysis temperature [J].
Fine, A ;
Penner, B .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1996, 28 (02) :262-265
[7]
HEMODYNAMIC STATE IN SEVERE CHRONIC RENAL-FAILURE - PATHOPHYSIOLOGICAL ASPECTS OF CARDIOVASCULAR FUNCTION AND THE IMPORTANCE OF BICARBONATE DIALYSIS [J].
HAMPL, H ;
SCHAFER, GE ;
KESSEL, M .
NEPHRON, 1985, 39 (02) :102-111
[8]
EFFECTS OF COOLER TEMPERATURE DIALYSATE ON HEMODYNAMIC STABILITY IN PROBLEM DIALYSIS PATIENTS [J].
JOST, CMT ;
AGARWAL, R ;
KHAIRELDIN, T ;
GRAYBURN, PA ;
VICTOR, RG ;
HENRICH, WL .
KIDNEY INTERNATIONAL, 1993, 44 (03) :606-612
[9]
KISHIMOTO T, 1986, DIALYSIS TRANSPLANT, V15, P329
[10]
KOCH KM, 1985, P EUR DIAL TRANSPLAN, V22, P155