A wavelet-based method for improving signal-to-noise ratio and contrast in MR images

被引:86
作者
Alexander, ME [1 ]
Baumgartner, R [1 ]
Summers, AR [1 ]
Windischberger, C [1 ]
Klarhoefer, M [1 ]
Moser, E [1 ]
Somorjai, RL [1 ]
机构
[1] Natl Res Council Canada, Inst Biodiagnost, Winnipeg, MB R3B 1Y6, Canada
关键词
de-noising; wavelets; signal-to-noise ratio; contrast; bias-variance tradeoff;
D O I
10.1016/S0730-725X(99)00128-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance (MR) images acquired with fast measurement often display poor signal-to-noise ratio (SNR) and contrast. With the advent of high temporal resolution imaging, there is a growing need to remove these noise artifacts. The noise in magnitude MR images is signal-dependent (Rician), whereas most de-noising algorithms assume additive Gaussian (white) noise. However, the Rician distribution only looks Gaussian at high SNR. Some recent work by Nowak employs a wavelet-based method for de-noising the square magnitude images, and explicitly takes into account the Rician nature of the noise distribution. In this article, we apply a wavelet de-noising algorithm directly to the complex image obtained as the Fourier transform of the raw k-space two-channel (real and imaginary) data. By retaining the complex image, we are able to de-noise not only magnitude images but also phase images. A multiscale (complex) wavelet-domain Wiener-type filter is derived. The algorithm preserves edges better when the Haar wavelet rather than smoother wavelets, such as those of Daubechies, are used. The algorithm was tested on a simulated image to which various levels of noise were added, on several EPI image sequences, each of different SNR, and on a pair of low SNR MR micro-images acquired using gradient echo and spin echo sequences. For the simulated data, the original image could be well recovered even for high values of noise (SNR approximate to 0 dB), suggesting that the present algorithm may provide better recovery of the contrast than Nowak's method. The mean-square error, bias, and variance are computed for the simulated images. Over a range of amounts of added noise, the present method is shown to give smaller bias than when using a soft threshold, and smaller variance than a hard threshold; in general, it provides a better bias-variance balance than either hard or soft threshold methods. For the EPI (MR) images, contrast improvements of up to 8% (for SNR = 33 dB) were found. In general, the improvement in contrast was greater the lower the original SNR, for example, up to 50% contrast improvement for SNR of about 20 dB in micro-imaging. Applications of the algorithm to the segmentation of medical images, to micro-imaging and angiography (where the correct preservation of; phase is important for flow encoding to be possible), as well as to de-noising time series of functional MR images, are discussed. (C) 2000 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:169 / 180
页数:12
相关论文
共 26 条
[1]  
ALDROUBI A, 1996, WAVELETS MED BIOL, P3
[2]  
Alexander M. E., 1999, P INT SOC MAGN RESON
[3]   Low-rank estimation of higher order statistics [J].
Andre, TF ;
Nowak, RD ;
VanVeen, BD .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1997, 45 (03) :673-685
[4]  
[Anonymous], 1998, PHYS A
[5]  
[Anonymous], 1996, Wavelets in Medicine and Biology
[6]  
[Anonymous], P IEEE INT C IM PROC
[7]  
BRUCE A, 1995, P SOC PHOTO-OPT INS, V2569, P270, DOI 10.1117/12.217582
[8]  
Coifman R. R., 1995, LECT NOTES STAT, V103, P125, DOI [DOI 10.1007/978-1-4612-2544-7_9, DOI 10.1002/CPA.3160410705, 10.1002/cpa.3160410705]
[9]   ORTHONORMAL BASES OF COMPACTLY SUPPORTED WAVELETS .2. VARIATIONS ON A THEME [J].
DAUBECHIES, I .
SIAM JOURNAL ON MATHEMATICAL ANALYSIS, 1993, 24 (02) :499-519
[10]  
Daubechies I., 1993, Ten Lectures of Wavelets, V28, P350