Development of an electrochemical immunosensor for aflatoxin M1 in milk with focus on matrix interference

被引:74
作者
Parker, Charlie O. [1 ]
Tothill, Ibtisam E. [1 ]
机构
[1] Cranfield Univ, Cranfield Hlth, Cranfield MK43 0AL, Beds, England
关键词
Immunosensor; Aflatoxin M1; Mycotoxins; Milk; SCREEN-PRINTED ELECTRODES; AMPEROMETRIC IMMUNOSENSOR; DAIRY-PRODUCTS; BOVINE URINE; COWS MILK; SAMPLES; ELISA; CHROMATOGRAPHY; IMMUNOASSAY; ACTIVATION;
D O I
10.1016/j.bios.2008.12.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A simple sensor method was developed for aflatoxin M, analysis to be applied directly with milk by using antibody modified screen-printed carbon working electrode with carbon counter and silver-silver chloride pseudo-reference electrode. A competitive ELISA assay format was constructed on the surface of the working electrode using 3,3,5',5'-tetramethylbenzidine dihyrochloride (TMB)/H2O2 electrochemical detection scheme with horseradish peroxidase (HRP) as the enzyme label. The performance of the assay and the sensor was optimised and characterised in pure buffer conditions before applying to milk samples. Extensive interference to the electroanalytical signal was observed upon the analysis of milk. Through a series of chemical fractionations of the milk, and testing the electrochemical properties of the fractions, the interference was attributed to whey proteins with focus towards alpha-lactalbumin. A simple pre-treatment technique of incorporating 18 mM calcium chloride, in the form of Dulbucco's PBS, in a 1: 1 ratio to the milk sample or standards and also to the washing buffer stabilised the whey proteins in solution and eliminate the interfering signal. The resulting immunosensor was interference free and achieved a limit of detection of 39 ng l(-1) with a linear dynamic detection range up to 1000 ng l(-1). The developed immunosensor method was compared to a commercial ELISA kit and an in-house HPLC method. The immunsensor was comparable, in term of sensitivity, but vastly superior in term of portability and cost therefore a key instrument for the detection of aflatoxin M-1 at the source of the contamination. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:2452 / 2457
页数:6
相关论文
共 50 条
[1]   Electrochemical immunosensor for determination of aflatoxin B1 in barley [J].
Ammida, NHS ;
Micheli, L ;
Palleschi, G .
ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) :159-164
[2]  
BASKEYFIELD D, 2001, THESIS CRANFIELD U U
[3]   Development of a disposable amperometric immunosensor for the detection of ecstasy and its analogues using screen-printed electrodes [J].
Butler, D ;
Pravda, M ;
Guilbault, GG .
ANALYTICA CHIMICA ACTA, 2006, 556 (02) :333-339
[4]   Development of an immunosensor for the detection of testosterone in bovine urine [J].
Conneely, Grainne ;
Aherne, Margaret ;
Lu, Huihui ;
Guilbault, George G. .
ANALYTICA CHIMICA ACTA, 2007, 583 (01) :153-160
[5]   Electrochemical impedance spectroscopy study of the adsorption behaviour of α-lactalbumin and β-casein at stainless steel [J].
Cosman, NP ;
Fatih, K ;
Roscoe, SG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 574 (02) :261-271
[6]   APPLICATION OF A DIPHASIC DIALYSIS MEMBRANE PROCEDURE FOR SURVEYING OCCURRENCE OF AFLATOXIN M(1) IN COMMERCIAL MILK [J].
DIAZ, S ;
DOMINGUEZ, L ;
PRIETA, J ;
BLANCO, JL ;
MORENA, MA .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (10) :2678-2680
[7]   A new electrochemical enzyme-linked immunosorbent assay for the screening of macrolide antibiotic residues in bovine meat [J].
Draisci, R ;
delli Quadri, F ;
Achene, L ;
Volpe, G ;
Palleschi, L ;
Palleschi, G .
ANALYST, 2001, 126 (11) :1942-1946
[8]   PLAQUE FORMATION AND ISOLATION OF PURE LINES WITH POLIOMYELITIS VIRUSES [J].
DULBECCO, R ;
VOGT, M .
JOURNAL OF EXPERIMENTAL MEDICINE, 1954, 99 (02) :167-182
[9]   AFLATOXIN M(1) IN HUMAN BREAST-MILK SAMPLES FROM VICTORIA, AUSTRALIA AND THAILAND [J].
ELNEZAMI, HS ;
NICOLETTI, G ;
NEAL, GE ;
DONOHUE, DC ;
AHOKAS, JT .
FOOD AND CHEMICAL TOXICOLOGY, 1995, 33 (03) :173-179
[10]  
Espinosa M, 1999, ELECTROANAL, V11, P1055, DOI 10.1002/(SICI)1521-4109(199910)11:14<1055::AID-ELAN1055>3.0.CO