Corneal and total optical in a unilateral aphakic aberrations patient

被引:55
作者
Barbero, S
Marcos, S
Merayo-Lloves, J
机构
[1] Consejo Super Invest Cient, Inst Opt, Madrid 28006, Spain
[2] Univ Valladolid, Inst Oftalmobiol Aplicada, Valladolid, Spain
关键词
D O I
10.1016/S0886-3350(02)01368-8
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose: To measure corneal and total optical aberrations in the normal and treated eye of a unilateral aphakic patient to (1) cross-validate techniques in an eye in which corneal and total aberrations should be almost identical (aphakic eye) and (2) compare the interactions of corneal and internal aberrations in the normal eye with those in the aphakic eye. Setting. Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain. Methods: Aberrations in both eyes of a unilateral aphakic patient were measured using laser ray tracing. Corneal aberrations were obtained from corneal elevation data measured with a corneal videokeratoscope (Humphrey Instruments) using custom software that performs virtual ray tracing on the measured front corneal surface. Results: There was a 98.4% correspondence between the total and corneal aberration pattern in the aphakic eye (6.5 mm pupil). In the normal eye, the total spherical aberration was much lower than the corneal spherical aberration; this did not occur in the aphakic eye. Conclusions: The posterior corneal surface contributed slightly to the aberrations in the normal cornea (2% at most). The crystalline lens appears to play a compensatory role in the total spherical aberration in normal eyes.
引用
收藏
页码:1594 / 1600
页数:7
相关论文
共 45 条
[1]
HOW ACCURATELY CAN VIDEOKERATOGRAPHIC SYSTEMS MEASURE SURFACE ELEVATION [J].
APPLEGATE, RA ;
NUNEZ, R ;
BUETTNER, J ;
HOWLAND, HC .
OPTOMETRY AND VISION SCIENCE, 1995, 72 (11) :785-792
[2]
Applegate RA, 2000, J REFRACT SURG, V16, P507
[3]
Applegate RA, 2000, J REFRACT SURG, V16, pS656
[4]
Contributions of the cornea and the lens to the aberrations of the human eye [J].
Artal, P ;
Guirao, A .
OPTICS LETTERS, 1998, 23 (21) :1713-1715
[5]
Contribution of the cornea and internal surfaces to the change of ocular aberrations with age [J].
Artal, P ;
Berrio, E ;
Guirao, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (01) :137-143
[6]
THROUGH FOCUS IMAGE QUALITY OF EYES IMPLANTED WITH MONOFOCAL AND MULTIFOCAL INTRAOCULAR LENSES [J].
ARTAL, P ;
MARCOS, S ;
NAVARRO, R ;
MIRANDA, I ;
FERRO, M .
OPTICAL ENGINEERING, 1995, 34 (03) :772-779
[7]
DESIGN OF ASPHERIC INTRAOCULAR LENSES [J].
ATCHISON, DA .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1991, 11 (02) :137-146
[8]
Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis [J].
Baek, TM ;
Lee, KH ;
Kagaya, F ;
Tomidokoro, A ;
Amano, S ;
Oshika, T .
OPHTHALMOLOGY, 2001, 108 (02) :317-320
[9]
Barbero S, 2002, J REFRACT SURG, V18, P263
[10]
Corneal topographic changes induced by different oblique cataract incisions [J].
Beltrame, G ;
Salvetat, ML ;
Chizzolini, M ;
Driussi, G .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (05) :720-727