Effect of glutaraldehyde concentration on the physical properties of polymerized hemoglobin-based oxygen carriers

被引:51
作者
Eike, JH [1 ]
Palmer, AF [1 ]
机构
[1] Univ Notre Dame, Dept Chem & Biomol Engn, Notre Dame, IN 46556 USA
关键词
D O I
10.1021/bp049974b
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Artificial blood substitutes based on glutaraldehyde cross-linked hemoglobin (PolyHb) are currently being developed for use in human subjects needing blood transfusions. Despite the commercial development of PolyHb dispersions, a systematic study of the effect of varying the glutaraldehyde to hemoglobin (G-Hb) molar ratio on the resulting PolyHb physical properties (molecular weight distribution and oxygen binding parameters) has not been conducted to date. The results of this study show that increasing the G-Hb molar ratio elicits a general decrease in the P-50 (partial pressure of oxygen at which Hb is half saturated with oxygen) and cooperativity and a simultaneous increase in the weight averaged molecular weight (M-w) of the PolyHb dispersion and methemoglobin (MetHb) level. Three PolyHb dispersions (20:1, 30:1, and 40:1 G-Hb molar ratios) displayed potential as artificial blood substitutes. The 20:1 PolyHb dispersion resulted in the presence of more intramolecularly cross-linked and non-cross-linked tetramers versus cross-linked species that were larger than a tetramer (similar to75% tetrameric and similar to25% higher-order species), lower MetHb level (8%), and P-50 (20.1 mmHg) similar in magnitude to that of non-cross-linked Hb. The 30:1 PolyHb dispersion consisted of more higher-order species (similar to76%), higher MetHb level (28%), and lower P-50 (13.3 mmHg). The 40:1 PolyHb dispersion resulted in a similar P-50 of 13.0 mmHg and similar MetHb level (30%); however, this PolyHb dispersion only consisted of species larger than a tetramer. The molecular weight distribution of PolyHb dispersions was determined using asymmetric flow field-flow fractionator (AFFF) coupled with multiangle static light scattering (MASLS). This is the first time that AFFF-MASLS has been used to characterize the molecular weight distribution of PolyHb dispersions.
引用
收藏
页码:1225 / 1232
页数:8
相关论文
共 29 条
[1]   ALDIMINE TO KETOAMINE ISOMERIZATION (AMADORI REARRANGEMENT) POTENTIAL AT THE INDIVIDUAL NONENZYMIC GLYCATION SITES OF HEMOGLOBIN-A - PREFERENTIAL INHIBITION OF GLYCATION BY NUCLEOPHILES AT SITES OF LOW ISOMERIZATION POTENTIAL [J].
ACHARYA, AS ;
ROY, RP ;
DORAI, B .
JOURNAL OF PROTEIN CHEMISTRY, 1991, 10 (03) :345-358
[2]   CLINICAL EXPERIENCE WITH HEMOGLOBIN-SALINE SOLUTIONS [J].
AMBERSON, WR ;
JENNINGS, JJ ;
RHODE, CM .
JOURNAL OF APPLIED PHYSIOLOGY, 1949, 1 (07) :469-489
[3]  
[Anonymous], 1965, Hawks physiological chemistry
[4]   A CRITICAL-REVIEW OF THE TOXICOLOGY OF GLUTARALDEHYDE [J].
BEAUCHAMP, RO ;
STCLAIR, MBG ;
FENNELL, TR ;
CLARKE, DO ;
MORGAN, KT ;
KARI, FW .
CRITICAL REVIEWS IN TOXICOLOGY, 1992, 22 (3-4) :143-174
[5]   THE EFFECTS OF HEMOGLOBIN SOLUTIONS ON RENAL FUNCTIONS IN MAN [J].
BRANDT, JL ;
FRANK, NR ;
LICHTMAN, HC .
BLOOD, 1951, 6 (11) :1152-1158
[6]  
DEVENUTO F, 1977, J LAB CLIN MED, V89, P509
[7]  
Dinkelmann S, 2002, INFUS THER TRANSFUS, V29, P167
[8]  
FEOLA M, 1988, SURG GYNECOL OBSTET, V166, P211
[9]  
FEOLA M, 1983, SURG GYNECOL OBSTET, V157, P399
[10]   NEPHROTOXICITY OF HEMOGLOBIN-SOLUTIONS [J].
FEOLA, M ;
SIMONI, J ;
TRAN, R ;
CANIZARO, PC .
BIOMATERIALS ARTIFICIAL CELLS AND ARTIFICIAL ORGANS, 1990, 18 (02) :233-249