Active compliance in robotic surgery - the use of force control as a dynamic constraint

被引:65
作者
Davies, BL
Harris, SJ
Lin, WJ
Hibberd, RD
Middleton, R
Cobb, JC
机构
[1] Department of Mechanical Engineering, Imperial College of Science, Technology and Medicine, London
[2] Department of Orthopaedic Surgery, Middlesex Hospital, London
关键词
robotic surgery; knee replacement; force control; active constraint;
D O I
10.1243/0954411971534403
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Robotic surgery can be carried out automatically by using a robot to move the cutting tool under position control. However, although the surgeon can observe the procedure on a visual display and has the ability to stop the operation in an emergency, he has little direct contact with the task. An alternative approach is to involve the surgeon more directly, by his moving a robot using active force control. The robot is then used to allow motion in preprogrammed regions, by the surgeon back-driving the robot motors, while preventing motion in prohibited areas. This active constraint robot (or ACROBOT) is described in this paper applied to knee surgery, in which the knee bones are accurately machined to allow the fitting of prosthetic knee implants. The ACROBOT is, however, ideally suited to a range of surgical procedures, because it allows the surgeon to feel the forces exerted during cutting and take appropriate action. This ability to be in direct control, while being constrained to cut within a permitted region, enhances safety and makes the system more acceptable to the medical community. The system of programmable constraint also allows the ACROBOT to provide the traditional benefits of robot surgery, namely the ability to machine complex geometrical surfaces very accurately and to make repetitive motions tirelessly. The system also has a potential for minimally invasive procedures. In knee surgery, for example, the robot could operate through a small incision in the skin and excise a volume into which a small, specially designed, unicompartmental prosthesis could fit.
引用
收藏
页码:285 / 292
页数:8
相关论文
共 12 条
[1]  
Davies B., 1993, 6 INT C ADV ROB TOK, P311
[2]  
DAVIES BL, 1992, INNOVATION TECHNOLOG, V13, P426
[3]  
FADDA M, 1992, INNOV TECH BIOL MED, V13, P394
[4]  
HO SC, 1995, 7 INT C ADV ROB SPAI
[5]  
HO SC, 1995, IEEE ENG MED BIOL, P292, DOI DOI 10.1109/51.391774
[6]  
HO SC, 1994, P EUR ROB INT SYST C, V3, P1235
[7]  
KIENZLE TC, 1995, IEEE ENG MED BIO MAY, P301, DOI DOI 10.1109/51.391773
[8]   ROBOT FORCE CONTROL - A REVIEW [J].
PATARINSKI, SP ;
BOTEV, RG .
MECHATRONICS, 1993, 3 (04) :377-398
[9]  
POTAMIANOS P, 1994, 1 INT S MED ROB COMP, V1
[10]  
TAYLOR RH, 1990, J ROBOTICS SOC J OCT, P111