Rapid and selective electrochemical determination of nitrite in cured meat in the presence of ascorbic acid

被引:26
作者
Badea, M
Amine, A
Benzine, M
Curulli, A
Moscone, D
Lupu, A
Volpe, G
Palleschi, G
机构
[1] Univ Roma Tor Vergata, Dipartimento Sci & Technol Chim, I-00133 Rome, Italy
[2] Univ Hassan 2, Fac Sci & Tech, Mohammadia 20650, Morocco
[3] CNR, Ist Studio Mat Nanostrutt Sez Roma 2, I-00161 Rome, Italy
关键词
nitrite determination; ascorbic acid interference; amperometric detection; carbon paste electrode;
D O I
10.1007/s00604-004-0220-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, fast and selective amperometric procedure for nitrite determination in cured meat based on the use of a carbon paste electrode is presented. Direct interference of ascorbic acid, which interferes with electrochemical detection, was eliminated by applying a cellulose acetate membrane of 100 Da molecular weight cut-off on the electrode. Indirect interference of ascorbic acid due to its auto-oxidation reaction and its reaction with nitrite is discussed. In order to stabilise the ascorbic acid, metaphosphoric acid and EDTA were added. In contrast to the standard spectrophotometric method, which requires careful control of pH and the use of carcinogenic reagents, amperometric determination of nitrite is simple, rapid, and works without reagents. Also, sample preparation is simpler because it requires neither heating to 80 degreesC nor the centrifugation steps of the official spectrophotometric method. The detection limit achieved was 14 ppb (0.2 muM) nitrite in the solution, which corresponds to a detection of 2.8 ppm in meat samples. The method was compared with the standard spectrophotometric procedure and applied to the detection of nitrites in cured meat samples with satisfactory results.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 27 条
[1]  
*AOAC, 1997, AOAC OFFICIAL METH S, V8
[2]   New electrochemical sensors for detection of nitrites and nitrates [J].
Badea, M ;
Amine, A ;
Palleschi, G ;
Moscone, D ;
Volpe, G ;
Curulli, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 509 (01) :66-72
[3]   Determination of nitrites in meat systems: An improved procedure [J].
Binstok, G ;
Campos, CA ;
Gerschenson, LN .
MEAT SCIENCE, 1996, 42 (04) :401-405
[4]   Dietary vitamin E and selenium and toxicity of nitrite and nitrate [J].
Chow, CK ;
Hong, CB .
TOXICOLOGY, 2002, 180 (02) :195-207
[5]   VOLTAMMETRIC BEHAVIOR OF NITRITE ION ON PLATINUM IN NEUTRAL AND WEAKLY ACIDIC MEDIA [J].
GUIDELLI, R .
ANALYTICAL CHEMISTRY, 1972, 44 (04) :745-&
[6]   Enzymic method for the determination of nitrite in meat and fish products [J].
Hamano, T ;
Mitsuhashi, Y ;
Aoki, N ;
Semma, M ;
Ito, Y ;
Oji, Y .
ANALYST, 1998, 123 (05) :1127-1129
[7]   FLOW-INJECTION DETERMINATION OF NITRITE AND NITRATE WITH BIAMPEROMETRIC DETECTION AT 2 PLATINUM WIRE ELECTRODES [J].
HULANICKI, A ;
MATUSZEWSKI, W ;
TROJANOWICZ, M .
ANALYTICA CHIMICA ACTA, 1987, 194 :119-127
[8]   Determination of ascorbic acid in food by column liquid chromatography with electrochemical detection using eluent for pre-run sample stabilization [J].
Iwase, H ;
Ono, I .
JOURNAL OF CHROMATOGRAPHY A, 1998, 806 (02) :361-364
[9]   The behaviour of ascorbic acid against nitrate and nitrite [J].
Karrer, P ;
Bendas, H .
HELVETICA CHIMICA ACTA, 1934, 17 :743-745
[10]   Nonenzymatic elimination of ascorbic acid in clinical samples [J].
Kayamori, Y ;
Katayama, Y ;
Urata, T .
CLINICAL BIOCHEMISTRY, 2000, 33 (01) :25-29