Effect of fibroin sponge coating on in vivo performance of knitted silk small diameter vascular grafts

被引:32
作者
Fukayama, Toshiharu [1 ]
Ozai, Yusuke [1 ]
Shimokawadoko, Haruka [2 ]
Aytemiz, Derya [2 ]
Tanaka, Ryou [1 ]
Machida, Noboru [3 ]
Asakura, Tetsuo [2 ]
机构
[1] Tokyo Univ Agr & Technol, Dept Vet Surg, Fuchu, Tokyo, Japan
[2] Tokyo Univ Agr & Technol, Dept Biotechnol, Koganei, Tokyo 184, Japan
[3] Tokyo Univ Agr & Technol, Lab Vet Clin Oncol, Fuchu, Tokyo, Japan
关键词
artificial vascular graft; endothelial cells; in vivo evaluation; silk fibroin; small diameter; INTIMAL HYPERPLASIA; BYPASS; SCAFFOLDS; COLLAGEN; SUTURES; GROWTH; VITRO; PTFE;
D O I
10.1080/15476278.2015.1093268
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
070307 [化学生物学]; 071010 [生物化学与分子生物学];
摘要
Vascular grafts under 5 mm or less in diameter are not developed due to a problem caused by early thrombus formation, neointimal hyperplasia, etc. Bombyx mori silk fibroin (SF) which has biodegradability and tissue infiltration is focused as tube and coating material of vascular grafts. Coating is an important factor to maintain the strength of the anastomotic region of vascular grafts, and to prevent the blood leak from the vascular grafts after implantation. Therefore, in this research, we focused on the SF concentration of the coating solution, and tissue infiltration and remodeling were compared among each SF concentration. Silk poly (-ethylene) glycol diglycidyl ether (PGDE) coating with concentrations of 1.0%, 2.5%, 5.0%, and 7.5% SF were applied for the double-raschel knitted small-sized vessel with 1.5mm diameter and 1cm in length. The grafts were implanted in the rat abdominal aorta and removed after 3 weeks or 3 months. Vascular grafts patency was monitored by ultrasound, and morphological evaluation was performed by histopathological examination. SF concentration had no significant effects on the patency rate. However, tissue infiltration was significantly higher in the sample of 2.5% SF in 3 weeks, and 1.0% and 2.5% SF in 3 months. Also, in comparison of length inside of the graft, stenosis were not found in 3 weeks, however, found with 5.0% and 7.5% in 3 months. From these results, it is clear that 2.5% SF coating is the most suitable concentration, based on the characteristics of less stenosis, early tissue infiltration, and less neointimal hyperplasia.
引用
收藏
页码:137 / 151
页数:15
相关论文
共 38 条
[1]
Silk-based biomaterials [J].
Altman, GH ;
Diaz, F ;
Jakuba, C ;
Calabro, T ;
Horan, RL ;
Chen, JS ;
Lu, H ;
Richmond, J ;
Kaplan, DL .
BIOMATERIALS, 2003, 24 (03) :401-416
[2]
Development of intimal hyperplasia in six different vascular prostheses [J].
Ao, PY ;
Hawthorne, WJ ;
Vicaretti, M ;
Fletcher, JP .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (03) :241-249
[3]
Characterization of silk sponge in the wet state using 13C solid state NMR for development of a porous silk vascular graft with small diameter [J].
Asakura, Tetsuo ;
Saotome, Toshiki ;
Aytemiz, Derya ;
Shimokawatoko, Haruka ;
Yagi, Takahito ;
Fukayama, Toshiharu ;
Ozai, Yusuke ;
Tanaka, Ryo .
RSC ADVANCES, 2014, 4 (09) :4427-4434
[4]
Small-Diameter Silk Vascular Grafts (3 mm Diameter) with a Double-Raschel Knitted Silk Tube Coated with Silk Fibroin Sponge [J].
Aytemiz, Derya ;
Sakiyama, Wataru ;
Suzuki, Yu ;
Nakaizumi, Naoki ;
Tanaka, Ryou ;
Ogawa, Yoko ;
Takagi, Yoshihide ;
Nakazawa, Yasumoto ;
Asakura, Tetsuo .
ADVANCED HEALTHCARE MATERIALS, 2013, 2 (02) :361-368
[5]
In vivo study of a model tissue-engineered small-diameter vascular bypass graft [J].
Baguneid, Mo ;
de Mel, Achala ;
Yildirimer, Lara ;
Fuller, Barry J. ;
Hamilton, George ;
Seifalian, Alexander M. .
BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2011, 58 (01) :14-24
[6]
Ballyk PD, 1998, J BIOMECH, V31, P229, DOI 10.1016/S0197-3975(97)00111-5
[7]
Long-term patency of small-diameter vascular graft made from fibroin, a silk-based biodegradable material [J].
Enomoto, Soichiro ;
Sumi, Makoto ;
Kajimoto, Kan ;
Nakazawa, Yasumoto ;
Takahashi, Rui ;
Takabayashi, Chiyuki ;
Asakura, Tetsuo ;
Sata, Masataka .
JOURNAL OF VASCULAR SURGERY, 2010, 51 (01) :155-164
[8]
A comparative study of alternative conduits for lower extremity revascularization: All-autogenous conduit versus prosthetic grafts [J].
Faries, PL ;
LoGerfo, FW ;
Arora, S ;
Hook, S ;
Pulling, MC ;
Akbari, CM ;
Campbell, DR ;
Pomposelli, FB .
JOURNAL OF VASCULAR SURGERY, 2000, 32 (06) :1080-1087
[9]
Biological Reaction to Small-Diameter Vascular Grafts Made of Silk Fibroin Implanted in the Abdominal Aortae of Rats [J].
Fukayama, Toshiharu ;
Takagi, Keisuke ;
Tanaka, Ryou ;
Hatakeyama, Yui ;
Aytemiz, Derya ;
Suzuki, Yu ;
Asakura, Tetsuo .
ANNALS OF VASCULAR SURGERY, 2015, 29 (02) :341-352
[10]
Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: A review [J].
Hiroaki Haruguchi ;
Satoshi Teraoka .
Journal of Artificial Organs, 2003, 6 (4) :227-235