Morphologic characteristics of atlantoaxial complex in rheumatoid arthritis and surgical consideration among Chinese

被引:21
作者
Chen, TY [1 ]
Lin, KL [1 ]
Ho, HH [1 ]
机构
[1] Chang Gung Mem Hosp, Dept Neurosurg, Taoyuan 333, Taiwan
关键词
rheumatoid arthritis; Chinese; atlantoaxial subluxation; morphology;
D O I
10.1097/00007632-200405010-00009
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A morphometric study of lateral mass from C1 to C2 and involving 42 patients with rheumatoid arthritis ( RA). Objective. To provide anatomic data on the lateral mass of the upper cervical spine and quantitatively assess structure feature of a C1-C2 lateral mass in RA and its association with adjacent structures. Summary of Background Data. No anatomic study on C1-C2 lateral mass in Chinese RA patients exists, nor is there a study describing the risk of transarticular screws fixation in these patients. Methods. Forty-two patients with RA were obtained for study of the bony structure of the C1-C2 lateral mass. Using reconstructed CT scan, the anatomic variability of bony structure to rheumatoid inflammatory change was assessed via C2 isthmus width and height measurement. The mediolateral diameter, superoinferior diameter, and sagittal length of the atlantoaxial lateral mass were also calculated. Additionally, the possible screw trajectory angles were assessed. Results. Forty-two patients displayed bony erosion of the C1-C2 mass. The dimension change of the C2 isthmus was weakly correlated with age and rheumatoid history. Furthermore, predominant destruction on either side of lateral mass is noted in 21.4% (n = 9) of patients. The mean shortest isthmus height of C2 is 4.69 +/- 1.66 mm, while its mean shortest width is 5.14 +/- 1.23 mm. Furthermore, the average distance between the anterior margin of C1 lateral mass and the same side posterior cortex of the C2 inferior facet is 36.53 +/- 3.94 mm. Meanwhile, the distance of coronal aspect of C1 lateral mass is 11.20 +/- 1.92 mm. The medial/lateral and caudo-cephalic inclinations of the isthmus with respect to the C2 inferior facet are 86.66 +/- 7.69degrees and 40.82 +/- 7.29degrees. Bilateral 3.5-mm screw placement could be safely achieved in only 30.9% (n = 13) of patients with chronic RA with upper cervical lesions. Conclusions. The work provides detailed bony data on the rheumatoid C2 isthmus and C1 structure. Anatomic variation in either side or both sides of the C2 isthmus is severe during erosion in patients with RA. Unilateral C1-C2 transarticular screw, modification of screw diameter, or alternative techniques for C1-C2 arthrodesis should be considered in most Chinese rheumatoid cases.
引用
收藏
页码:1000 / 1004
页数:5
相关论文
共 22 条
[1]   THE AMERICAN-RHEUMATISM-ASSOCIATION 1987 REVISED CRITERIA FOR THE CLASSIFICATION OF RHEUMATOID-ARTHRITIS [J].
ARNETT, FC ;
EDWORTHY, SM ;
BLOCH, DA ;
MCSHANE, DJ ;
FRIES, JF ;
COOPER, NS ;
HEALEY, LA ;
KAPLAN, SR ;
LIANG, MH ;
LUTHRA, HS ;
MEDSGER, TA ;
MITCHELL, DM ;
NEUSTADT, DH ;
PINALS, RS ;
SCHALLER, JG ;
SHARP, JT ;
WILDER, RL ;
HUNDER, GG .
ARTHRITIS AND RHEUMATISM, 1988, 31 (03) :315-324
[2]   Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement [J].
Bloch, O ;
Holly, LT ;
Park, J ;
Obasi, C ;
Kim, K ;
Johnson, JP .
JOURNAL OF NEUROSURGERY, 2001, 95 (01) :74-79
[3]  
CHANG SC, 2001, J RADIOL TECH, V25, P9
[4]   Arteriovenous fistula as a complication of C1-2 transarticular screw fixation - Case report and review of the literature [J].
Coric, D ;
Branch, CL ;
Wilson, JA ;
Robinson, JC .
JOURNAL OF NEUROSURGERY, 1996, 85 (02) :340-343
[5]   Biomechanical characteristics of C1-2 cable fixations [J].
Dickman, CA ;
Crawford, NR ;
Paramore, CG .
JOURNAL OF NEUROSURGERY, 1996, 85 (02) :316-322
[6]  
DICKMAN CA, 1998, SURG CRANIOVERTEBRAL, P761
[7]  
HAID JRW, 1992, SPINE, V17, P480
[8]   C1-C2 transarticular screw fixation for atlantoaxial instability: A 6-year experience [J].
Haid, RW ;
Subach, BR ;
McLaughlin, MR ;
Rodts, GE ;
Wahlig, JB .
NEUROSURGERY, 2001, 49 (01) :65-68
[9]   Anatomic study for ideal and safe posterior C1-C2 transarticular screw fixation [J].
Jun, BY .
SPINE, 1998, 23 (15) :1703-1707
[10]   Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique [J].
Madawi, AA ;
Casey, ATH ;
Solanki, GA ;
Tuite, G ;
Veres, R ;
Crockard, HA .
JOURNAL OF NEUROSURGERY, 1997, 86 (06) :961-968