Mycobacterial growth and bacterial contamination in the mycobacteria growth indicator tube and BACTEC 460 culture systems

被引:46
作者
Cornfield, DB [1 ]
Beavis, KG [1 ]
Greene, JA [1 ]
Bojak, M [1 ]
Bondi, J [1 ]
机构
[1] THOMAS JEFFERSON UNIV HOSP,DEPT PATHOL ANAT & CELL BIOL,PHILADELPHIA,PA 19107
关键词
D O I
10.1128/JCM.35.8.2068-2071.1997
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The BACTEC 460 system currently provides the most rapid detection of mycobacterial growth, but the system is radiometric and requires needles to inoculate specimens through the bottle's septum. The Mycobacteria Growth Indicator Tube (MGIT) system has a liquid medium, like the BACTEC system, and does noe require needles when inoculating specimens. We compared mycobacterium growth from 510 specimens in the two systems, Average time to acid-fast bacillus (AFB) detection and identification to the species level was less with the BACTEC system, but this result was statistically significant only for AFB detection in specimens containing Mycobacterium avium-M. intracellulare complex, The contamination rate with MGIT was 29%; the BACTEC rate was 5%. To investigate MGIT contamination, we initiated a second study with changes in specimen processing, The MGIT contamination rate was reduced to 12%; the BACTEC rate was mot significantly affected (5.5%), The most likely explanation for the contamination in MGIT is the richness of its medium compared to the BACTEC medium, Cost analysis for the two systems in a laboratory that processes 4,500 specimens a year is presented, The data suggest that the BACTEC 460 and the MGIT systems are approximately equivalent in cost and ability to support the growth of AFB. The MGIT system appears safer and easier to use and was preferred by laboratory personnel, but it cannot currently be used for blood specimens or antituberculosis susceptibility testing.
引用
收藏
页码:2068 / 2071
页数:4
相关论文
共 9 条
  • [1] Comparison of mycobacteria growth indicator tube with BACTEC 460 for detection and recovery of mycobacteria from clinical specimens
    Badak, FZ
    Kiska, DL
    Setterquist, S
    Hartley, C
    OConnell, MA
    Hopfer, RL
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (09) : 2236 - 2239
  • [2] *BECT DICK CO, 1994, BBL MGIT PROD DET MY
  • [3] BOWLES EJ, 1995, 95 GEN M AM SOC MICR, P142
  • [4] EVANS K, 1995, 95 GEN M AM SOC MICR, P25
  • [5] Kent P. T., 1985, PUBLIC HLTH MYCOBACT
  • [6] MIDDLEBROOK G, 1977, AM REV RESPIR DIS, V115, P1066
  • [7] NEUMANN MA, 1995, 95 GEN M AM SOC MICR, P24
  • [8] Siddiqi SH, 1995, BACTEC 460 TB SYSTEM
  • [9] Zar J. H., 1974, BIOSTATISTICAL ANAL