A real-time plantar pressure feedback device for foot unloading

被引:31
作者
Femery, VG
Moretto, PG
Hespel, JMG
Thévenon, A
Lensel, G
机构
[1] Fac Sci Sport & Educ, Lab Etud Motricite Humaine, F-59790 Ronchin, France
[2] Hop Swynghedauw, Serv Med Phys & Readaptat, Lille, Thevenon, France
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2004年 / 85卷 / 10期
关键词
gait; motor skills; plantar ulcer; pressure; orthotic devices; rehabilitation;
D O I
10.1016/j.apmr.2003.11.031
中图分类号
R49 [康复医学];
学科分类号
100215 [康复医学与理疗学];
摘要
Objective: To develop and test a plantar pressure control device that provides both visual and auditory feedback and is suitable for correcting plantar pressure distribution patterns in persons susceptible to neuropathic foot ulceration. Design: Pilot test. Setting: Sports medicine laboratory in a university in France. Participant: One healthy man in his mid thirties. Interventions: Not applicable. Main Outcome Measures: A device was developed based on real-time feedback, incorporating an acoustic alarm and visual signals, adjusted to a specific pressure load. Plantar pressure measured during walking, at 6 sensor locations over 27 steps under 2 different conditions: (1) natural and (2) unloaded in response to device feedback. Results: The subject was able to modify his gait in response to the auditory and visual signals. He did not compensate for the decrease of peak pressure under the first metarsal by increasing the duration of the load shift under this area. Gait pattern modification centered on a mediolateral load shift. Conculsions: The auditory signal provided a warning system alerting the user to potentially harmful plantar pressures. The visual signal warned of the degree of pressure. People who have lost nociceptive perception, as in cases of diabetic neuropathy, may be able to change their walking pattern in response to the feedback provided by this device. The visual may have diagnostic value in determining plantar pressures in such patients. This pilot test indicates that further studies are warranted. (C) 2004 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation.
引用
收藏
页码:1724 / 1728
页数:5
相关论文
共 28 条
[1]
AbuFaraj ZO, 1997, J REHABIL RES DEV, V34, P187
[2]
Elevated peak plantar pressures in patients who have Charcot arthropathy [J].
Armstrong, DG ;
Lavery, LA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (03) :365-369
[3]
BASMAJIAN JV, 1981, ARCH PHYS MED REHAB, V62, P469
[4]
An augmented auditory feedback device [J].
Batavia, M ;
Gianutsos, JG ;
Kambouris, M .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (12) :1389-1392
[5]
BRUDNY J, 1974, ARCH PHYS MED REHAB, V55, P403
[6]
CAVANAGH P.R., 1992, INT J CLIN FOOT SCI, V2, P185, DOI [10.1016/0958-2592(92)90047-S, DOI 10.1016/0958-2592(92)90047-S, 10.1016/0958-2592, DOI 10.1016/0958-2592]
[7]
Chow DHK, 2000, J REHABIL RES DEV, V37, P255
[8]
TRANSDUCERS FOR FOOT PRESSURE MEASUREMENT - SURVEY OF RECENT DEVELOPMENTS [J].
COBB, J ;
CLAREMONT, DJ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (04) :525-532
[9]
FEEDBACK THERAPY FOR IMPROVING HEEL CONTACT AND TOE OFF MOTION DURING AMBULATION [J].
FLEISS, O ;
FLEISS, H ;
POKORNY, H .
INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1980, 3 (04) :497-503
[10]
Balance and mobility following stroke: Effects of physical therapy interventions with and without biofeedback/forceplate training [J].
Geiger, RA ;
Allen, JB ;
O'Keefe, J ;
Hicks, RR .
PHYSICAL THERAPY, 2001, 81 (04) :995-1005