Relative roles of spatial and intensive cues in the discrimination of spatial tactile stimuli

被引:23
作者
Gibson, GO [1 ]
Craig, JC [1 ]
机构
[1] Indiana Univ, Dept Psychol, Bloomington, IN 47405 USA
来源
PERCEPTION & PSYCHOPHYSICS | 2002年 / 64卷 / 07期
关键词
D O I
10.3758/BF03194759
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Two psychophysical measures of tactile sensitivity-grating-orientation (GO) and smooth-grooved (SG) discrimination-were used to determine tactile spatial acuity with and without an intermediate surface (latex glove) interposed between the contactor and the skin. Measures were made at three locations that varied in sensitivity and in density of innervation of the primary afferent fibers: the index fingerpad (fingertip), palmar surface of the proximal phalanx (fingerbase); and the thenar eminence (palm). Neurophysiological studies have suggested that the density of innervation of SAI fibers is a limiting factor in spatial acuity. In the present study, without a glove, the GO thresholds varied as a function of location. With the glove, increases in the GO thresholds were relatively uniform and modest. Without a glove, however, the SG thresholds were well below the GO thresholds, and changing the site of stimulation had little effect on the threshold. With a glove, the SG thresholds increased by 100% to more than 300% as in comparison with those in the no-glove condition. The largest increases occurred. at the less sensitive locations. The results of the GO task are consistent with the view that GO is a valid measure of spatial acuity. The results of the SG task, however, are inconsistent with previous results and suggest that both spatial and intensive factors are involved in this task.
引用
收藏
页码:1095 / 1107
页数:13
相关论文
共 44 条
[1]   THE EFFECTS OF VARIOUS THICKNESSES OF CHEMICAL PROTECTIVE GLOVES ON MANUAL DEXTERITY [J].
BENSEL, CK .
ERGONOMICS, 1993, 36 (06) :687-696
[2]  
Brisben A. J., 1992, Society for Neuroscience Abstracts, V18, P1545
[3]   SOME PHYSICAL FACTORS INFLUENCING TACTILE PERCEPTION WITH DISPOSABLE NON-STERILE GLOVES [J].
BURKE, FJT ;
WATTS, DC ;
WILSON, NHF .
JOURNAL OF DENTISTRY, 1989, 17 (02) :72-76
[4]   Grating orientation as a measure of tactile spatial acuity [J].
Craig, JC .
SOMATOSENSORY AND MOTOR RESEARCH, 1999, 16 (03) :197-206
[5]  
Craig JC, 1998, SOMATOSENS MOT RES, V15, P29
[6]   A correction and a comment on Craig and Lyle (2001) [J].
Craig, JC ;
Lyle, KB .
PERCEPTION & PSYCHOPHYSICS, 2002, 64 (03) :504-506
[7]   A comparison of tactile spatial sensitivity on the palm and fingerpad [J].
Craig, JC ;
Lyle, KB .
PERCEPTION & PSYCHOPHYSICS, 2001, 63 (02) :337-347
[8]   The two-point threshold: Not a measure of tactile spatial resolution [J].
Craig, JC ;
Johnson, KO .
CURRENT DIRECTIONS IN PSYCHOLOGICAL SCIENCE, 2000, 9 (01) :29-32
[9]  
Cunningham J L, 1992, J Ir Dent Assoc, V38, P12
[10]   INNERVATION DENSITY OF MECHANORECEPTIVE FIBERS SUPPLYING GLABROUS SKIN OF THE MONKEYS INDEX FINGER [J].
DARIANSMITH, I ;
KENINS, P .
JOURNAL OF PHYSIOLOGY-LONDON, 1980, 309 (DEC) :147-155