Oxygen delivery and consumption in the microcirculation after extreme hemodilution with perfluorocarbons

被引:53
作者
Cabrales, P
Tsai, AG
Frangos, JA
Briceño, JC
Intaglietta, M
机构
[1] Univ Calif San Diego, Dept Bioengn, La Jolla, CA 92093 USA
[2] La Jolla Bioengn Inst, La Jolla, CA 92037 USA
[3] Univ Los Andes, Dept Mech Engn, Bogota, Colombia
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2004年 / 287卷 / 01期
关键词
hyperoxia; functional capillary density; oxygen-carrying capacity; blood substitutes; tissue oxygen delivery;
D O I
10.1152/ajpheart.01166.2003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The oxygen transport capacity of fluorocarbons was investigated in the hamster chamber window model microcirculation to determine the rate at which oxygen is delivered to the tissue in conditions of extreme hemodilution [hematocrit (Hct) 11%]. Hydroxyethlyl starch (HES 200; 200 kDa molecular mass) was used as a plasma expander for two isovolemic hemodilutions performed with 10% HES 200 until a Hct of 65%. A third step reduced the Hct to 75% of baseline and was performed with either HES 200 or a 60% perfluorocarbon (PFC) emulsion. Comparisons of HES 200-only-hemodiluted animals versus 4.2 g/kg PFC emulsion-hemodiluted animals were made at 21% and 100% normobaric oxygen ventilation. It was found that systemic and microvascular oxygen delivery was 25% and 400% higher in the PFC animals compared with HES 200 animals, respectively, showing that PFCs deliver oxygen to the tissue when combined with hyperoxic ventilation in the present experiments, with no evidence of vasoconstriction or impaired microvascular function. Oxygen ventilation ( 100%) led to a positive base excess for the PFC group (5.5 +/- 2.5 mmol/l) versus a negative balance (-0.8 +/- 1.4 mmol/l) for the HES 200 group, suggesting that microvascular findings corresponded to systemic events.
引用
收藏
页码:H320 / H330
页数:11
相关论文
共 36 条
[1]   Statistics notes - How to randomise [J].
Altman, DG ;
Bland, JM .
BRITISH MEDICAL JOURNAL, 1999, 319 (7211) :703-704
[2]   In vivo pO2 measurements in hamster skinfold by recessed pO2 microelectrodes and phosphorescence quenching are in agreement [J].
Buerk, DG ;
Tsai, AG ;
Intaglietta, M ;
Johnson, PC .
MICROCIRCULATION, 1998, 5 (2-3) :219-225
[3]   Measurement of the cardiac output in small animals by thermodilution [J].
Cabrales, P ;
Acero, C ;
Intaglietta, M ;
Tsai, AG .
MICROVASCULAR RESEARCH, 2003, 66 (02) :77-82
[4]   QUANTITATION OF RHYTHMIC DIAMETER CHANGES IN ARTERIAL MICROCIRCULATION [J].
COLANTUONI, A ;
BERTUGLIA, S ;
INTAGLIETTA, M .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (04) :H508-H517
[5]   TECHNICAL REPORT - A NEW CHAMBER TECHNIQUE FOR MICRO-VASCULAR STUDIES IN UNANESTHETIZED HAMSTERS [J].
ENDRICH, B ;
ASAISHI, K ;
GOTZ, A ;
MESSMER, K .
RESEARCH IN EXPERIMENTAL MEDICINE, 1980, 177 (02) :125-134
[6]   FLOW EFFECTS ON PROSTACYCLIN PRODUCTION BY CULTURED HUMAN-ENDOTHELIAL CELLS [J].
FRANGOS, JA ;
ESKIN, SG ;
MCINTIRE, LV ;
IVES, CL .
SCIENCE, 1985, 227 (4693) :1477-1479
[7]  
Habler O, 1997, ACTA ANAESTH SCAND, V41, P256
[8]   IV Perflubron emulsion versus autologous transfusion in severe normovolemic anemia: effects on left ventricular perfusion and function [J].
Habler, O ;
Kleen, M ;
Hutter, J ;
Podtschaske, A ;
Tiede, M ;
Kemming, G ;
Welte, M ;
Corso, C ;
Batra, S ;
Keipert, P ;
Faithfull, S ;
Messmer, K .
RESEARCH IN EXPERIMENTAL MEDICINE, 1998, 197 (06) :301-318
[9]   Hemodilution and intravenous perflubron emulsion as an alternative to blood transfusion: effects on tissue oxygenation during profound hemodilution in anesthetized dogs [J].
Habler, OP ;
Kleen, MS ;
Hutter, JW ;
Podtschaske, AH ;
Tiede, M ;
Kemming, GI ;
Welte, MV ;
Corso, CO ;
Batra, S ;
Keipert, PE ;
Faithfull, NS ;
Messmer, KFW .
TRANSFUSION, 1998, 38 (02) :145-155
[10]   CAPILLARY FLOW VELOCITY-MEASUREMENTS INVIVO AND INSITU BY TELEVISION METHODS [J].
INTAGLIETTA, M ;
SILVERMAN, NR ;
TOMPKINS, WR .
MICROVASCULAR RESEARCH, 1975, 10 (02) :165-179