Detection of Norovirus genogroup I and II by multiplex real-time RT-PCR using a 3′-minor groove binder-DNA probe

被引:97
作者
Hoehne, Marina [1 ]
Schreier, Eckart [1 ]
机构
[1] Robert Koch Inst, D-13353 Berlin, Germany
关键词
D O I
10.1186/1471-2334-6-69
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Due to an increasing number of norovirus infections in the last years rapid, specific, and sensitive diagnostic tools are needed. Reverse transcriptase-polymerase chain reactions ( RTPCR) have become the methods of choice. To minimize the working time and the risk of carryover contamination during the multi-step procedure of PCR the multiplex real-time RT-PCR for the simultaneous detection of genogroup I (GI) and II (GII) offers advantages for the handling of large amounts of clinical specimens. Methods: We have developed and evaluated a multiplex one-tube RT-PCR using a combination of optimized GI and GII specific primers located in the junction between ORF1 and ORF2 of the norovirus genome. For the detection of GI samples, a 3'-minor groove binder-DNA probe (GI-MGB-probe) were designed and used for the multiplex real-time PCR. Results: Comparable results to those of our in-house nested PCR and monoplex real-time-PCR were only obtained using the GI specific MGB-probe. The MGB-probe forms extremely stable duplexes with single-stranded DNA targets, which enabled us to design a shorter probe ( length 15 nucleotides) hybridizing to a more conserved part of the GI sequences. 97% of 100 previously norovirus positive specimens ( tested by nested PCR and/or monoplex real-time PCR) were detected by the multiplex real-time PCR. A broad dynamic range from 2 x 10(boolean AND) 1 to 2 x 10(boolean AND) 7 genomic equivalents per assay using plasmid DNA standards for GI and GII were obtained and viral loads between 2.5 x 10(boolean AND) 2 and 2 x 10(boolean AND) 12 copies per ml stool suspension were detected. Conclusion: The one-tube multiplex RT real-time PCR using a minor groove binder - DNA probe for GI is a fast, specific, sensitive and cost-effective tool for the detection of norovirus infections in both mass outbreaks and sporadic cases and may have also applications in food and environmental testing.
引用
收藏
页数:6
相关论文
共 31 条
  • [1] DETECTION AND DIFFERENTIATION OF ANTIGENICALLY DISTINCT SMALL ROUND-STRUCTURED VIRUSES (NORWALK-LIKE VIRUSES) BY REVERSE TRANSCRIPTION PCR AND SOUTHERN HYBRIDIZATION
    ANDO, T
    MONROE, SS
    GENTSCH, JR
    JIN, Q
    LEWIS, DC
    GLASS, RI
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (01) : 64 - 71
  • [2] Diagnosis of noncultivatable gastroenteritis viruses, the human caliciviruses
    Atmar, RL
    Estes, MK
    [J]. CLINICAL MICROBIOLOGY REVIEWS, 2001, 14 (01) : 15 - +
  • [3] Evaluation and comparison of two commercial enzyme-linked immunosorbent assay kits for detection of antigenically diverse human noroviruses in stool samples
    Burton-MacLeod, JA
    Kane, EM
    Beard, RS
    Hadley, LA
    Glass, RI
    Ando, T
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (06) : 2587 - 2595
  • [4] *CDCP, 2003, MMWR-MORBID MORTAL W, V52, P41
  • [5] Evaluation of a commercial enzyme immunoassay for detection of norovirus in outbreak specimens
    Dimitriadis, A
    Marshall, JA
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2005, 24 (09) : 615 - 618
  • [6] DUIZER E, 2004, EUROSURVEILLANCE WEE, V8, P1
  • [7] Felsenstein J., 2005, PHYLIP PHYLOGENY INF, DOI DOI 10.1111/J.1096-0031.1989.TB00562.X
  • [8] Detection and characterization of norovirus outbreaks in Germany:: Application of a one-tube RT-PCR using a fluorogenic real-time detection system
    Höhne, M
    Schreier, E
    [J]. JOURNAL OF MEDICAL VIROLOGY, 2004, 72 (02) : 312 - 319
  • [9] Characterization of a novel human calicivirus that may be a naturally occurring recombinant
    Jiang, X
    Espul, C
    Zhong, WM
    Cuello, H
    Matson, DO
    [J]. ARCHIVES OF VIROLOGY, 1999, 144 (12) : 2377 - 2387
  • [10] Coexistence of multiple genotypes, including newly identified genotypes, in outbreaks of gastroenteritis due to Norovirus in Japan
    Kageyama, T
    Shinohara, M
    Uchida, K
    Fukushi, S
    Hoshino, FB
    Kojima, S
    Takai, R
    Oka, T
    Takeda, N
    Katayama, K
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (07) : 2988 - 2995