Regeneration of peripheral nerve gaps with a polyglycolic acid-collagen tube

被引:65
作者
Inada, Y
Morimoto, S
Takakura, Y
Nakamura, T
机构
[1] Kyoto Univ, Inst Frontier Med Sci, Dept Bioartificial Organs, Sakyo Ku, Kyoto 6068507, Japan
[2] Inada Hosp, Dept Orthopaed Surg, Nara, Japan
[3] Nara Rehabil Ctr, Dept Neurol, Nara, Japan
[4] Nara Med Univ, Dept Orthopaed Surg, Nara, Japan
关键词
biodegradable polymer; collagen; nerve regeneration; nerve tube; peripheral nerve injury;
D O I
10.1227/01.NEU.0000134388.86603.11
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: The aim of this study was to report by means of objective methods on the effectiveness of a nerve reconstruction procedure using a bioresorbable tube in two patients. Our previous successes in regenerating canine peripheral nerves across long distances (80-mm gaps) using a bioabsorbable tube have led us to investigate the value of such a tube for the treatment of human patients with chronic nerve injuries. METHODS: The device was made from a cylindrically woven polyglycolic acid tube filled with a Collagen sponge. It was designed to be resorbed after nerve regeneration. Peripheral sensory nerve defects in two patients with neuroma and pain were reconstructed using this tube. Patient 1 (a 62-year-old man) had a 20-mm defect of the proper digital nerve, and Patient 2 (a 56-year-old woman) had a 65-mm defect of the superficial peroneal nerve. RESULTS: After surgery, both patients recovered from the unpleasant sensations and intolerable pain. In Patient 1, functional recovery was objectively identified at 2 months, and conduction velocity of the nerve recovered to 49.1 m/s. In Patient 2, conduction velocity of the nerve was determined to be 16.9 m/s at 5 months. Current perception threshold testing indicated that sensory nerve function had been recovered by 65 days after surgery. CONCLUSION: This work represents the first precise clinical evaluation, performed under objective evaluation criteria, of sensory recovery achieved using a nerve tube, suggesting that the use of a polyglycolic acid-collagen tube has the potential to become a viable alternative to conventional autografting for the repair of peripheral nerve defects.
引用
收藏
页码:640 / 646
页数:7
相关论文
共 34 条
[1]  
AITKEN JT, 1962, J ANAT, V96, P121
[2]   ARTERIAL SPASTICITY AND COLD INTOLERANCE IN RELATION TO TIME AFTER DIGITAL REPLANTATION [J].
BACKMAN, C ;
NYSTROM, A ;
BACKMAN, C ;
BJERLE, P .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1993, 18B (05) :551-555
[3]  
BENELIYAHU DJ, 2000, AM J PAIN MANAGE, V10, P60
[4]  
BORA FW, 1987, J HAND SURG-AM, V12A, P685
[5]   CHANGES IN CONDUCTION VELOCITY AND FIBRE SIZE PROXIMAL TO PERIPHERAL NERVE LESIONS [J].
CRAGG, BG ;
THOMAS, PK .
JOURNAL OF PHYSIOLOGY-LONDON, 1961, 157 (02) :315-&
[6]   LONG-TERM EVALUATION OF NERVE REGENERATION IN A BIODEGRADABLE NERVE GUIDE [J].
DENDUNNEN, WFA ;
VANDERLEI, B ;
SCHAKENRAAD, JM ;
BLAAUW, EH ;
STOKROOS, I ;
PENNINGS, AJ ;
ROBINSON, PH .
MICROSURGERY, 1993, 14 (08) :508-515
[7]   EFFECTS OF REGIONAL INTRAVENOUS GUANETHIDINE BLOCK IN POSTTRAUMATIC COLD INTOLERANCE IN HAND AMPUTEES [J].
ENGKVIST, O ;
WAHREN, LK ;
WALLIN, G ;
TOREBJORK, E ;
NYSTROM, B .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1985, 10B (02) :145-150
[8]  
Hagiwara Akeo, 2002, Gan To Kagaku Ryoho, V29, P2202
[9]   Experimental study on in situ tissue engineering of the stomach by an acellular collagen sponge scaffold graft [J].
Hori, Y ;
Nakamura, T ;
Matsumoto, K ;
Kurokawa, Y ;
Satomi, S ;
Shimizu, Y .
ASAIO JOURNAL, 2001, 47 (03) :206-210
[10]   PATTERNS OF THERMOREGULATION ASSOCIATED WITH COLD INTOLERANCE AFTER DIGITAL REPLANTATION [J].
ISOGAI, N ;
FUKUNISHI, K ;
KAMIISHI, H .
MICROSURGERY, 1995, 16 (08) :556-565