Effect of a novel interspinous implant on lumbar spinal range of motion

被引:13
作者
Gunzburg, Robert [1 ]
Szpalski, Marek [2 ]
Callary, Stuart A. [3 ]
Colloca, Christopher J. [4 ]
Kosmopoulos, Victor [5 ,6 ]
Harrison, Deed [7 ]
Moore, Robert J. [8 ]
机构
[1] Eeuwfeestkliniek Hosp, Dept Orthopaed Surg, Antwerp, Belgium
[2] IRIS S Teaching Hosp, Hop Iris Sud, Dept Orthoped, Brussels, Belgium
[3] Royal Adelaide Hosp, Dept Orthopaed & Trauma, Adelaide, SA 5000, Australia
[4] Arizona State Univ, Dept Kinesiol, Biomech Lab, Tempe, AZ USA
[5] Univ N Texas, Hlth Sci Ctr, Dept Orthopaed Surg, Bone & Joint Res Ctr, Ft Worth, TX USA
[6] John Peter Smith Hosp, Dept Orthopaed Surg, Ft Worth, TX 76104 USA
[7] CBP Nonprofit Inc, Evanston, WY USA
[8] Adelaide Ctr Spinal Res, Adelaide, SA, Australia
关键词
Interspinous implant; Biomechanics; Spondylolisthesis; Lumbar spine; Kinematics; IN-VITRO; X-STOP; DYNAMIC NEUTRALIZATION; DISC DEGENERATION; FOLLOW-UP; STENOSIS; INSTABILITY; SYSTEM; FIXATION; SPONDYLOLISTHESIS;
D O I
10.1007/s00586-009-0890-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Interspinous devices have been introduced to provide a minimally invasive surgical alternative for patients with lumbar spinal stenosis or foraminal stenosis. Little is known however, of the effect of interspinous devices on intersegmental range of motion (ROM). The aim of this in vivo study was to investigate the effect of a novel minimally invasive interspinous implant, InSwing(A (R)), on sagittal plane ROM of the lumbar spine using an ovine model. Ten adolescent Merino lambs underwent a destabilization procedure at the L1-L2 level simulating a stenotic degenerative spondylolisthesis (as described in our earlier work; Spine 15:571-576, 1990). All animals were placed in a side-lying posture and lateral radiographs were taken in full flexion and extension of the trunk in a standardized manner. Radiographs were repeated following the insertion of an 8-mm InSwing(A (R)) interspinous device at L1-L2, and again with the implant secured by means of a tension band tightened to 1 N/m around the L1 and L2 spinous processes. ROM was assessed in each of the three conditions and compared using Cobb's method. A paired t-test compared ROM for each of the experimental conditions (P < 0.05). After instrumentation with the InSwing(A (R)) interspinous implant, the mean total sagittal ROM (from full extension to full flexion) was reduced by 16% from 6.3A degrees to 5.3 +/- A 2.7A degrees. The addition of the tension band resulted in a 43% reduction in total sagittal ROM to 3.6 +/- A 1.9A degrees which approached significance. When looking at flexion only, the addition of the interspinous implant without the tension band did not significantly reduce lumbar flexion, however, a statistically significant 15% reduction in lumbar flexion was observed with the addition of the tension band (P = 0.01). To our knowledge, this is the first in vivo study radiographically showing the advantage of using an interspinous device to stabilize the spine in flexion. These results are important findings particularly for patients with clinical symptoms related to instable degenerative spondylolisthesis.
引用
收藏
页码:696 / 703
页数:8
相关论文
共 40 条
[1]
LUMBOSACRAL SEGMENTAL MOTION IN NORMAL INDIVIDUALS - HAVE WE BEEN MEASURING INSTABILITY PROPERLY [J].
BODEN, SD ;
WIESEL, SW .
SPINE, 1990, 15 (06) :571-576
[2]
Interspinous process devices in the lumbar spine [J].
Bono, Christopher M. ;
Vaccaro, Alexander R. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (03) :255-261
[3]
Evaluation of lumbar spine motion with dynamic X-ray -: A reliability analysis [J].
Cakir, Balkan ;
Richter, Marcus ;
Kaefer, Wolfram ;
Wieser, Michael ;
Puhl, Wolfhart ;
Schmidt, Rene .
SPINE, 2006, 31 (11) :1258-1264
[4]
Dynamic interspinous process technology [J].
Christie, SD ;
Song, JK ;
Fessler, RG .
SPINE, 2005, 30 (16) :S73-S78
[5]
DAI LY, 1989, SPINE, V14, P523
[6]
Failure of the Wallis interspinous implant to lower the incidence of recurrent lumbar disc herniations in patients undergoing primary disc excision [J].
Floman, Yizhar ;
Millgram, Michael A. ;
Smorgick, Yossi ;
Rand, Nahshon ;
Ashkenazi, Ely .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (05) :337-341
[7]
Dynamic neutralisation of the lumbar spine confirmed on a new lumbar spine simulator in vitro [J].
Freudiger, S ;
Dubois, G ;
Lorrain, M .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1999, 119 (3-4) :127-132
[8]
The relationship between disc degeneration, facet joint osteoarthritis, and stability of the degenerative lumbar spine [J].
Fujiwara, A ;
Tamai, K ;
An, HS ;
Kurihashi, A ;
Lim, TH ;
Yoshida, H ;
Saotome, K .
JOURNAL OF SPINAL DISORDERS, 2000, 13 (05) :444-450
[9]
Graf H., 1992, Rachis, V412, P123
[10]
Grevitt M P, 1995, Eur Spine J, V4, P169, DOI 10.1007/BF00298241