Optimisation of a solid-phase microextraction method for the determination of parabens in water samples at the low ng per litre level

被引:144
作者
Canosa, P. [1 ]
Rodriguez, I. [1 ]
Rubi, E. [1 ]
Bollain, M. H. [1 ]
Cela, R. [1 ]
机构
[1] Univ Santiago de Compostela, Dept Quim Analit Nutr & Bromatol, Inst Invest & Anal Alimentario, Santiago De Compostela 15782, Spain
关键词
parabens; SPME; on-fibre silylation; GC-MS/MS; water analysis;
D O I
10.1016/j.chroma.2006.03.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A procedure for the determination of five esters of p-hydroxybenzoic acid (parabens) in water samples is presented. Analytes (methyl, ethyl, propyl, butyl and benzyl paraben) are concentrated on a solid-phase microextraction (SPME) fibre, converted on their tert-butyldimethylsilyl derivatives and selectively determined using gas chromatography in combination with tandem mass spectrometry (GC-MS/MS). Influence of different factors on the efficiency of extraction and on-fibre derivatization steps is described in detail. For all species, the highest enrichment factors were achieved using a polyacrylate (PA) fibre exposed directly to stirred water samples, containing 150mg/ml of sodium chloride, at room temperature. Performance of the further on-fibre derivatization reaction was also maximum at room temperature, considering a short exposition period of the SPME fibre to vapours of the silylation reagent. Under optimised conditions, the proposed method achieved quantification limits from 0.001 to 0.025 ng/ml and it was free of matrix effects; therefore, external calibration can be used as the quantification technique. From our knowledge, this work describes the first application of SPME and gas chromatography to the determination of parabens in water. The analysis of a limited number of real samples revealed the presence of parabens in raw sewage water at concentrations up to 3 ng/ml. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 29 条
  • [1] Determination of perfluorocarboxylic acids in aqueous matrices by ion-pair solid-phase microextraction-in-port derivatization-gas chromatography-negative ion chemical ionization mass spectrometry
    Alzaga, R
    Bayona, JM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1042 (1-2) : 155 - 162
  • [2] Analysis of multiple endocrine disruptors in environmental waters via wide-spectrum solid-phase extraction and dual-polarity ionization LC-ion trap-MS/MS
    Benijts, T
    Lambert, W
    De Leenheer, A
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (03) : 704 - 711
  • [3] Sonic spray ionization applied to liquid chromatography/mass spectrometry analysis of endocrine-disrupting chemicals in environmental water samples
    Benijts, T
    Günther, W
    Lambert, W
    De Leenheer, A
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (16) : 1866 - 1872
  • [4] Validation of HPLC analysis of 2-phenoxyethanol, 1-phenoxypropan-2-ol, methyl, ethyl, propyl, butyl and benzyl 4-hydroxybenzoate (parabens) in cosmetic products, with emphasis on decision limit and detection capability
    Borremans, M
    Van Loco, J
    Roos, P
    Goeyens, L
    [J]. CHROMATOGRAPHIA, 2004, 59 (1-2) : 47 - 53
  • [5] Trace analysis of technical nonylphenol, bisphenol A and 17α-ethinylestradiol in wastewater using solid-phase microextraction and gas chromatography-mass spectrometry
    Braun, P
    Moeder, M
    Schrader, S
    Popp, P
    Kuschk, P
    Engewald, W
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 988 (01) : 41 - 51
  • [6] Aquatic degradation of triclosan and formation of toxic chlorophenols in presence of low concentrations of free chlorine
    Canosa, P
    Morales, S
    Rodríguez, I
    Rubí, E
    Cela, R
    Gómez, M
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (7-8) : 1119 - 1126
  • [7] Optimization of solid-phase microextraction conditions for the determination of triclosan and possible related compounds in water samples
    Canosa, P
    Rodriguez, I
    Rubí, E
    Cela, R
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1072 (01) : 107 - 115
  • [8] Carpinteiro J, 2004, J CHROMATOGR A, V1056, P179, DOI 10.1016/S0021-9673(04)01082-9
  • [9] Determining leaching of bisphenol A from plastic containers by solid-phase microextraction and gas chromatography-mass spectrometry
    Chang, CM
    Chou, CC
    Lee, MR
    [J]. ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) : 41 - 47
  • [10] Concentrations of parabens in human breast tumours
    Darbre, PD
    Aljarrah, A
    Miller, WR
    Coldham, NG
    Sauer, MJ
    Pope, GS
    [J]. JOURNAL OF APPLIED TOXICOLOGY, 2004, 24 (01) : 5 - 13