Plasma brain natriuretic peptide to detect preclinical ventricular systolic or diastolic dysfunction - A community-based study

被引:222
作者
Redfield, MM
Rodeheffer, RJ
Jacobsen, SJ
Mahoney, DW
Bailey, KR
Burnett, JC
机构
[1] Mayo Clin & Mayo Fdn, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Sect Hlth Sci Res, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Biostat Sect, Rochester, MN 55905 USA
关键词
natriuretic peptides; ventricular dysfunction; diastole; systole; diagnosis;
D O I
10.1161/01.CIR.0000130845.38133.8F
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Preclinical systolic or diastolic dysfunction is associated with increased morbidity and mortality. We postulated that plasma brain natriuretic peptide (BNP) might serve as a biomarker for preclinical ventricular dysfunction (PCVD) but that the discriminatory values for BNP may vary with age and sex. Methods and Results-We measured BNP, systolic and diastolic ventricular function, and clinical parameters in 2042 randomly selected residents of Olmsted County, Minn, aged 45 years or older. For preclinical systolic dysfunction, the areas under the receiver operating characteristics curve were higher for those with more severe (0.82 to 0.92) than any (0.51 to 0.74) systolic dysfunction and were similar in men and women and in younger and older persons. For preclinical diastolic dysfunction, the areas under the receiver operating characteristics curve were higher for those with moderate-to-severe (0.74 to 0.79) than any (0.52 to 0.68) diastolic dysfunction and were similar regardless of age or sex. Optimal discriminatory values of BNP varied with age and sex. Considering the prevalence of preclinical systolic or diastolic dysfunction and the predictive characteristics observed, using BNP to screen for PCVD would necessitate echo in 10% to 40% of those screened, with most confirmatory echocardiograms being negative, and would miss 10% to 60% of those affected. Conclusions-BNP is a suboptimal screening test for PCVD in the population.
引用
收藏
页码:3176 / 3181
页数:6
相关论文
共 22 条
[1]   Predictive value of systolic and diastolic function for incident congestive heart failure in the elderly: The Cardiovascular Health Study [J].
Aurigemma, GP ;
Gottdiener, JS ;
Shemanski, L ;
Gardin, J ;
Kitzman, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (04) :1042-1048
[2]   Mitral ratio of peak early to late diastolic filling velocity as a predictor of mortality in middle-aged and elderly adults - The strong heart study [J].
Bella, JN ;
Palmieri, V ;
Roman, MJ ;
Liu, JE ;
Welty, TK ;
Lee, ET ;
Fabsitz, RR ;
Howard, BV ;
Devereux, RB .
CIRCULATION, 2002, 105 (16) :1928-1933
[3]   RULING OUT OR RULING IN DISEASE WITH THE MOST SENSITIVE OR SPECIFIC DIAGNOSTIC-TEST - SHORT-CUT OR WRONG TURN [J].
BOYKO, EJ .
MEDICAL DECISION MAKING, 1994, 14 (02) :175-179
[4]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[5]   Ethical considerations in the provision of controversial screening tests [J].
Doukas, DJ ;
Fetters, M ;
Ruffin, MT ;
McCullough, LB .
ARCHIVES OF FAMILY MEDICINE, 1997, 6 (05) :486-490
[6]   Diastolic heart failure in the community [J].
Hart C.Y.T. ;
Redfield M.M. .
Current Cardiology Reports, 2000, 2 (5) :461-469
[7]  
Heidenreich P, 2002, CIRCULATION, V106, P725
[8]   Utility of B-natriuretic peptide in detecting diastolic dysfunction - Comparison with Doppler velocity recordings [J].
Lubien, E ;
DeMaria, A ;
Krishnaswamy, P ;
Clopton, P ;
Koon, J ;
Kazanegra, R ;
Gardetto, N ;
Wanner, E ;
Maisel, AS .
CIRCULATION, 2002, 105 (05) :595-601
[9]   Evaluation of brain natriuretic peptide as marker of left ventricular dysfunction and hypertrophy in the population [J].
Luchner, A ;
Burnett, JC ;
Jougasaki, M ;
Hense, HW ;
Heid, IM ;
Muders, F ;
Riegger, GAJ ;
Schunkert, H .
JOURNAL OF HYPERTENSION, 2000, 18 (08) :1121-1128
[10]   History of the Rochester Epidemiology Project [J].
Melton, LJ .
MAYO CLINIC PROCEEDINGS, 1996, 71 (03) :266-274