Operation of fault tolerant machines with winding failures

被引:107
作者
Haylock, JA [1 ]
Mecrow, BC [1 ]
Jack, AG [1 ]
Atkinson, DJ [1 ]
机构
[1] Univ Newcastle Upon Tyne, Dept Elect & Elect Engn, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
基金
英国工程与自然科学研究理事会;
关键词
fault tolerance; permanent magnet drives; shorted turn detection; condition monitoring;
D O I
10.1109/60.815095
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper examines winding faults in a demonstrator drive, based on a specification for an aircraft fuel pump. This drive has been designed with a;degree of inherent fault tolerance and is capable of continued operation in the presence of a variety of faults. Some of the most severe faults arise fi om winding insulation failure within a phase of the machine. A method of detecting turn to turn short circuits which can result from winding insulation breakdown is presented, along with a strategy for continued post fault operation of the drive. The detection method operates in real time, requires no additional sensors and is sufficiently sensitive to detect even a single shorted turn.
引用
收藏
页码:1490 / 1495
页数:6
相关论文