Overview on advances in capillary electrophoresis-mass spectrometry of carbohydrates: A tabulated review

被引:70
作者
Campa, Cristiana
Coslovi, Anna
Flamigni, Anna
Rossi, Marco
机构
[1] Bracco Imaging SpA, CRM Trieste, I-34012 Trieste, Italy
[2] Univ Trieste, Dept Biochem Biophys & Macromol Chem, Trieste, Italy
关键词
capillary electrophoresis-electrospray mass spectrometry; carbohydrates; glycoconjugates; glycosides;
D O I
10.1002/elps.200500960
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The increasing interest for carbohydrates as holder of essential bioinformations has boosted their full characterization through analytical techniques. The intent of this review is to summarize the recent trends regarding on-line and off-line CE-MS coupling for carbohydrate analysis. A statistical survey on the articles that use derivatizing agents as well as on the analyzer and type of instrument coupling (i.e. on- or off-line) is depicted. From a general overview it can be concluded that, whereas derivatization might be useful for the detection of neutral carbohydrates improving separation selectivity with volatile buffers and increasing sensitivity of the MS detection, relatively few works with derivatized carbohydrates were found; this was noticed in particular for glycosides and saccharides carrying ionizable groups, which are normally analyzed without any chemical modification. The most applied coupling is the on-line sheath-liquid interface; for online applications, ESI is the sole source used, whilst the most common analyzer is the IT MSn is often exploited, as fragmentation increases the achieved structural information. CE-MS turned out to be mainly used for the analysis of carbohydrates in drug development (i.e. study of oligosaccharides from pathogens, carbohydrate-based drugs and drug metabolites), in nutrition and for characterization of glycans from glycoproteins. The reader will find elucidating tables regarding these recent CE-MS applications, including the main information on the analysis conditions. Comments are meant to help the immediate focus on the usefulness of the analytical technique and predict the difficulties found during analysis and, in case, their overcoming.
引用
收藏
页码:2027 / 2050
页数:24
相关论文
共 97 条
[1]   Improved capillary electrophoretic separation and mass spectrometric detection of oligosaccharides [J].
An, HJ ;
Franz, AH ;
Lebrilla, CB .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1004 (1-2) :121-129
[2]   Glycoprofiling with micro-arrays of glycoconjugates and lectins [J].
Angeloni, S ;
Ridet, JL ;
Kusy, N ;
Gao, H ;
Crevoisier, F ;
Guinchard, S ;
Kochhar, S ;
Sigrist, H ;
Sprenger, N .
GLYCOBIOLOGY, 2005, 15 (01) :31-41
[3]   Enhancement of sample loadings for the analysis of oligosaccharides isolated from Pseudomonas aeruginosa using transient isotachophoresis and capillary zone electrophoresis-electrospray-mass spectrometry [J].
Auriola, S ;
Thibault, P ;
Sadovskaya, I ;
Altman, E .
ELECTROPHORESIS, 1998, 19 (15) :2665-2676
[4]  
Bateman Kevin P, 2003, Methods Mol Biol, V213, P219
[5]   Evaluation of glycoalkaloids in tubers of genetically modified virus Y-resistant potato plants (var. Desiree) by non-aqueous capillary electrophoresis coupled with electrospray ionization mass spectrometry (NACE-ESI-MS) [J].
Bianco, G ;
Schmitt-Kopplin, P ;
Crescenzi, A ;
Comes, S ;
Kettrup, A ;
Cataldi, TRI .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (06) :799-804
[6]  
Bianco G, 2002, ELECTROPHORESIS, V23, P2904, DOI 10.1002/1522-2683(200209)23:17&lt
[7]  
2904::AID-ELPS2904&gt
[8]  
3.0.CO
[9]  
2-1
[10]   Sheathless reverse-polarity capillary electrophoresis-electrospray-mass spectrometry for analysis of underivatized glycoconjugates [J].
Bindila, L ;
Peter-Katalinic, J ;
Zamfir, A .
ELECTROPHORESIS, 2005, 26 (7-8) :1488-1499