Birefringence of magnetite-based magnetic fluids: The effect of the surface-coating layer

被引:9
作者
Morais, PC [1 ]
Neto, KS
Bakuzis, AF
Da Silva, MF
Buske, N
机构
[1] Univ Brasilia, Inst fis Nucl Fis Aplicada, BR-79091997 Brasilia, DF, Brazil
[2] Berlin Heart AG, D-12247 Berlin, Germany
关键词
birefringence; magnetic fluids; magnetite; permeability;
D O I
10.1109/TMAG.2002.802497
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, water-based and hydrocarbon-based magnetic fluids (M-Fs) containing Fe3O4 nanoparticles are investigated using static magnetic birefringence measurements. A strong dependence of the birefringence signal upon the magnetic permeability is found. In addition to the field dependence of the magnetic permeability, inclusion of dimers in the description of the birefringence signal yields excellent agreement between parameters obtained from birefringence and high-resolution microscopy data.
引用
收藏
页码:3228 / 3230
页数:3
相关论文
共 18 条
[1]  
Berkovsky B.M., 1993, Magnetic Fluids: Engineering Applications
[2]  
BUSKE N, 1994, PROG COLL POL SCI S, V95, P175
[3]   ENERGY BARRIERS FOR THERMAL REVERSAL OF INTERACTING SINGLE DOMAIN PARTICLES [J].
CHEN, WJ ;
ZHANG, SF ;
BERTRAM, HN .
JOURNAL OF APPLIED PHYSICS, 1992, 71 (11) :5579-5584
[4]   Biomedical applications of maghemite ferrofluid [J].
Halbreich, A ;
Roger, J ;
Pons, JN ;
Geldwerth, D ;
Da Silva, MF ;
Roudier, M ;
Bacri, JC .
BIOCHIMIE, 1998, 80 (5-6) :379-390
[5]  
HALBREICH A, 2001, MICROSPHERES MICROCA, V3, P459
[6]   APPROACH TO ELONGATED FINE-PARTICLE MAGNETS [J].
JACOBS, IS ;
BEAN, CP .
PHYSICAL REVIEW, 1955, 100 (04) :1060-1067
[7]  
Jordan A, 1997, SCIENTIFIC AND CLINICAL APPLICATIONS OF MAGNETIC CARRIERS, P569
[8]   Particle sizing of magnetite-based magnetic fluid using atomic force microscopy: A comparative study with electron microscopy and birefringence [J].
Lacava, BM ;
Azevedo, RB ;
Silva, LP ;
Lacava, ZGM ;
Neto, KS ;
Buske, N ;
Bakuzis, AF ;
Morais, PC .
APPLIED PHYSICS LETTERS, 2000, 77 (12) :1876-1878
[9]   Nanoparticle sizing: a comparative study using atomic force microscopy, transmission electron microscopy, and ferromagnetic resonance [J].
Lacava, LM ;
Lacava, BM ;
Azevedo, RB ;
Lacava, ZGM ;
Buske, N ;
Tronconi, AL ;
Morais, PC .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2001, 225 (1-2) :79-83
[10]   Magnetic resonance of magnetite nanoparticles dispersed in mesoporous copolymer matrix [J].
Morais, PC ;
Lima, ECD ;
Rabelo, D ;
Reis, AC ;
Pelegrini, F .
IEEE TRANSACTIONS ON MAGNETICS, 2000, 36 (05) :3038-3040