Measurement and interpretation of QT dispersion

被引:45
作者
Batchvarov, V [1 ]
Malik, M [1 ]
机构
[1] St George Hosp, Sch Med, Dept Cardiol Sci, London SW17 0RE, England
关键词
D O I
10.1053/pcad.2000.0420325
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
QT dispersion was proposed as an index of the spatial inhomogeneity of ventricular recovery times. The results of studies that found significant correlation between dispersion of ventricular recovery times measured with monophasic action potentials and QT dispersion were interpreted as proof of the direct link between QT dispersion and the dispersion of ventricular recovery times. Later it was shown that QT dispersion is not a direct reflection of the spatial variation of the recovery times and cannot be used for quantification of this variation. The interlead variability of the QT intervals is a result of different projections of the spatial T-wave loop into the various electrocardiographic leads. The reliability of both manual and automatic measurement of QT dispersion is low and is often of the order of the differences of Qt dispersion between different patient groups. The measurement reliability is influenced by intrinsic factors (eg, amplitude of the T wave) and extrinsic factors (eg, noise, paper speed of recording, instruments for manual measurements, and type of algorithm and interalgorithmic settings for automatic measurement). There is very little to choose between the different indices of expression of QT dispersion, as well as between the different lead configurations used for its measurement. QT dispersion is not simply a result of measurement error, but a crude measure of abnormalities during the whole course of repolarization. Only grossly prolonged QT dispersion (eg, ≥100 ms), must be interpreted simply as a sign of the abnormal course of the repolarization, and inferences about the actual dispersion of the ventricular recovery times should not be made. Newer concepts of assessment of the morphology of the T wave are already emerging and will probably be of higher clinical value. (C) 2000 by W.B. Saunders Company.
引用
收藏
页码:325 / 344
页数:20
相关论文
共 127 条
  • [1] UNIDENTIFIED INFORMATION-CONTENT OF ELECTROCARDIOGRAM
    ABILDSKOV, JA
    BURGESS, MJ
    URIE, PM
    LUX, RL
    WYATT, RF
    [J]. CIRCULATION RESEARCH, 1977, 40 (01) : 3 - 7
  • [2] Spatial, temporal and wavefront direction characteristics of 12-lead T-wave morphology
    Acar, B
    Yi, G
    Hnatkova, K
    Malik, M
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (05) : 574 - 584
  • [3] QT INTERVAL PROLONGATION IN ACUTE MYOCARDIAL-INFARCTION
    AHNVE, S
    [J]. EUROPEAN HEART JOURNAL, 1985, 6 : 85 - 95
  • [4] CIRCUS MOVEMENT IN RABBIT ATRIAL MUSCLE AS A MECHANISM OF TACHYCARDIA .2. ROLE OF NONUNIFORM RECOVERY OF EXCITABILITY IN OCCURRENCE OF UNIDIRECTIONAL BLOCK, AS STUDIED WITH MULTIPLE MICROELECTRODES
    ALLESSIE, MA
    BONKE, FIM
    SCHOPMAN, FJG
    [J]. CIRCULATION RESEARCH, 1976, 39 (02) : 168 - 177
  • [5] ANDRIKOPOULOS G, 1999, PACING CLIN ELECTROP, V20, P805
  • [6] ANTZELEVITCH C, 1997, MONOPHASIC ACTION PO, P216
  • [7] ANZELEVICH C, 1996, J ELECTROCARDIOL S, V28, P131
  • [8] ANZELEVICH C, 1991, CIRC RES, V69, P1427
  • [9] SEQUENCE OF REPOLARIZATION ON VENTRICULAR SURFACE IN DOG
    AUTENRIETH, G
    SURAWICZ, B
    KUO, CS
    [J]. AMERICAN HEART JOURNAL, 1975, 89 (04) : 463 - 469
  • [10] AYTEMIR K, 2000, IN PRESS PACING CLIN