摘要
Objective: To determine whether the use of nitric oxide (NO)releasing polymers coated onto the inner surface of extracorporeal circuits can reduce platelet consumption and activation in the absence of systemic heparinization using a rabbit model of veno-venous extracorporeal circulation. Design: Prospective, controlled trial Setting: Research laboratory at an academic medical institution. Subjects: New Zealand White Rabbits Interventions: Anesthetized, tracheotomized, and ventilated New Zealand White rabbits were injected with freshly prepared, (111)ln(oxine), labeled single donor platelets through the external jugular vein. After baseline measurements, these animals were placed on venovenous extracorporeal circulation through a l-m control circuit or NO test circuit for 4 hrs at a blood flow rate of 109-118 mL/min via roller pump. Four groups were studied: systemically heparinized control circuits, systemically heparinized NO test circuits, nonheparinized control circuits, and nonheparinized NO test circuits. Platelet counts, fibrinogen levels, and plasma free indium levels were measured hourly. Circuits were rinsed and retained for gamma counting after the 4-hr run or when the circuit clotted. Four animals, one from each group, did not receive radiolabeled platelets so that the circuits could he preserved for scanning electron microscopic examination after the 4-hr study. Measurements and Main Results: Platelet consumption was significantly reduced in both the heparinized and nonheparinized NO test groups when compared with the controls (p <.0001 and p <.0004, respectively). Platelet adhesion to the extracorporeal circuits was significantly reduced in the nonheparinized test circuits when compared with the controls (p <.05). Scanning electron microscopic examination of the circuits revealed that in the absence of heparin and in the presence of a NO-releasing surface, platelets retained their spherical nonactivated shape. Conclusions: The incorporation of NO into the surface of extracorporeal circuits reduces platelet consumption and eliminates the need for systemic heparinization in a rabbit model of extracorporeal circulation.
引用
收藏
页码:915 / 920
页数:6
相关论文
共 22 条
[1]  
ANNICH GM, 1997, ASAIO J, V43, P7
[2]   ADENOSINE DIPHOSPHATE-INDUCED PLATELET AGGREGATION IN SUSPENSIONS OF WASHED RABBIT PLATELETS [J].
ARDLIE, NG ;
PACKHAM, MA ;
MUSTARD, JF .
BRITISH JOURNAL OF HAEMATOLOGY, 1970, 19 (01) :7-&
[3]   NITRIC-OXIDE FUNCTIONS AS AN INHIBITOR OF PLATELET-ADHESION UNDER FLOW CONDITIONS [J].
DEGRAAF, JC ;
BANGA, JD ;
MONCADA, S ;
PALMER, RMJ ;
DEGROOT, PG ;
SIXMA, JJ .
CIRCULATION, 1992, 85 (06) :2284-2290
[4]  
Edmunds L H Jr, 1995, ASAIO J, V41, P824, DOI 10.1097/00002480-199510000-00002
[5]   Thromboresistant chemical sensors using combined nitric oxide release ion sensing polymeric films [J].
EspadasTorre, C ;
Oklejas, V ;
Mowery, K ;
Meyerhoff, ME .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (09) :2321-2322
[6]  
ESPADASTORRE C, 1996, THESIS U MICHIGAN AN, P70
[7]  
Gorman RC, 1996, J THORAC CARDIOV SUR, V112, P557, DOI 10.1016/S0022-5223(96)70295-7
[8]   FUNCTION OF HUMAN PLATELETS DURING EXTRACORPOREAL-CIRCULATION [J].
HENNESSY, VL ;
HICKS, RE ;
NIEWIAROWSKI, S ;
EDMUNDS, LH ;
COLMAN, RW .
AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 232 (06) :H622-H628
[9]   FLOW-INJECTION DETERMINATION OF NITRITE AND NITRATE WITH BIAMPEROMETRIC DETECTION AT 2 PLATINUM WIRE ELECTRODES [J].
HULANICKI, A ;
MATUSZEWSKI, W ;
TROJANOWICZ, M .
ANALYTICA CHIMICA ACTA, 1987, 194 :119-127
[10]  
MACALLISTER RJ, 1996, JIFCC, V8, P152