Electrocatalysis and amperometric detection of alditols and sugars at a gold-nickel composite electrode in anion-exchange chromatography

被引:23
作者
Casella, IG [1 ]
Guascito, MR [1 ]
Cataldi, TRI [1 ]
机构
[1] Univ Basilicata, Dipartimento Chim, I-85100 Potenza, Italy
关键词
D O I
10.1016/S0003-2670(99)00420-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel Au-Ni composite electrode prepared by cathodic precipitation/deposition of nickel hydroxide on the gold surface was characterised. The resulting composite electrode was evaluated as an amperometric sensor in flow injection analysis and anion-exchange chromatography for the quantitation of alditols and simple carbohydrates. Constant potential detection at +0.6V vs Ag/AgCl and a pulsed detection mode were employed, and their applicability and usefulness discussed. The detection Limits (S/N = 3) for all investigated compounds, in both modes of detection, ranged between 1.5 and 7.5 pmol injected. Linear dynamic ranges spanned over four and three orders of magnitude when the composite electrode was used in the DC or pulsed mode. The main advantage of the Au-Ni composite electrode is that detection selectivity can be tailored by the choice of the detection mode and by the polarisation potential. As an example, we show how to detect common carbohydrates in tea powder using the constant potential detection mode. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 29 条
[1]  
Arthur D.M. Mac, 1970, J ELECTROCHEM SOC, V117, P422
[2]   CHEMICALLY MODIFIED ELECTRODES IN LIQUID-CHROMATOGRAPHY DETECTION - A REVIEW [J].
BALDWIN, RP ;
THOMSEN, KN .
TALANTA, 1991, 38 (01) :1-16
[3]  
Bektiwaska-Brzezinska M., 1985, ELECTROCHIM ACTA, V30, P1193
[4]   AN INSITU WEIGHING STUDY OF THE MECHANISM FOR THE FORMATION OF THE ADSORBED OXYGEN MONOLAYER AT A GOLD ELECTRODE [J].
BRUCKENSTEIN, S ;
SHAY, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 188 (1-2) :131-136
[5]   Voltammetric and XPS investigations of nickel hydroxide electrochemically dispersed on gold surface electrodes [J].
Casella, IG ;
Guascito, MR ;
Sannazzaro, MG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 462 (02) :202-210
[6]   Copper dispersed into polyaniline films as an amperometric sensor in alkaline solutions of amino acids and polyhydric compounds [J].
Casella, IG ;
Cataldi, TRI ;
Guerrieri, A ;
Desimoni, E .
ANALYTICA CHIMICA ACTA, 1996, 335 (03) :217-225
[7]   Applications of a copper-modified gold electrode for amperometric detection of polar aliphatic compounds by anion-exchange chromatography [J].
Casella, IG ;
Gatta, M ;
Desimoni, E .
JOURNAL OF CHROMATOGRAPHY A, 1998, 814 (1-2) :63-70
[8]   ELECTROCATALYTIC OXIDATION AND LIQUID-CHROMATOGRAPHIC DETECTION OF ALIPHATIC-ALCOHOLS AT A NICKEL-BASED GLASSY-CARBON MODIFIED ELECTRODE [J].
CASELLA, IG ;
CATALDI, TRI ;
SALVI, AM ;
DESIMONI, E .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3143-3150
[9]   NICKEL-OXIDE DISPERSED IN A GRAPHITE/POLY(VINYL CHLORIDE) COMPOSITE MATRIX FOR AN ELECTROCATALYTIC AMPEROMETRIC SENSOR OF ALDITOLS IN FLOW-INJECTION ANALYSIS [J].
CATALDI, TRI ;
CENTONZE, D .
ANALYTICA CHIMICA ACTA, 1995, 307 (01) :43-48
[10]   Development of a carbon composite electrode made from polyethylene and graphite powder modified with copper(I) oxide [J].
Cataldi, TRI ;
Centonze, D .
ANALYTICA CHIMICA ACTA, 1996, 326 (1-3) :107-115