Characterization of antibodies against benzo[a]pyrene with thermodynamic and kinetic constants

被引:14
作者
Länge, K
Griffin, G
Vo-Dinh, T
Gauglitz, G
机构
[1] Univ Tubingen, Inst Phys & Theoret Chem, D-72076 Tubingen, Germany
[2] Oak Ridge Natl Lab, Div Life Sci, Oak Ridge, TN 37831 USA
关键词
antibody; affinity; avidity; kinetic; benzo[a]pyrene;
D O I
10.1016/S0039-9140(01)00668-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Antibodies of a polyclonal antiserum against benzo[a]pyrene were characterized by determining thermodynamic and kinetic constants of the antigen-antibody reaction. Label-free binding assays with optical detection based on reflectometric interference spectroscopy were performed to determine these constants. Different evaluation methods for kinetic measurements were compared. Also, cross-reactivity against two other polycyclic aromatic hydrocarbons, chrysene and pyrene, was checked. The affinity constant between the antibodies and benzo[a]pyrene in homogeneous phase was determined to be K = (5.3 +/- 0.3) x 10(7) M-1 which was in the middle of the usual range of antibody affinities. The association rate constant for the reaction at the surface was determined to be (3.8 +/- 0.9) x 10(5) M-1 s(-1), the dissociation rate constant as (9.7 +/- 0.5) x 10(-3) s(-1). Different evaluation methods applied to the kinetic measurements led to the same results. This antiserum would be suitable for the selective determination of benzo[a]pyrene in concentrated samples. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1153 / 1161
页数:9
相关论文
共 31 条
[1]   Effectiveness of protein A for antibody immobilization for a fiber optic biosensor [J].
Anderson, GP ;
Jacoby, MA ;
Ligler, FS ;
King, KD .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (04) :329-336
[2]  
ATKINS PW, 1990, PHYSICAL CHEM
[3]   A streptavidin surface on planar glass substrates for the detection of biomolecular interaction [J].
Birkert, O ;
Haake, HM ;
Schütz, A ;
Mack, J ;
Brecht, A ;
Jung, G ;
Gauglitz, G .
ANALYTICAL BIOCHEMISTRY, 2000, 282 (02) :200-208
[4]  
BJORCK A, 1979, NUMERISCHE METHODEN
[5]   A DIRECT OPTICAL IMMUNOSENSOR FOR ATRAZINE DETECTION [J].
BRECHT, A ;
PIEHLER, J ;
LANG, G ;
GAUGLITZ, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :289-299
[6]   OPTIMIZED LAYER SYSTEMS FOR IMMUNOSENSORS BASED ON THE RIFS TRANSDUCER [J].
BRECHT, A ;
GAUGLITZ, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (05) :360-366
[7]   Label free optical immunoprobes for pesticide detection [J].
Brecht, A ;
Gauglitz, G .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :219-233
[8]  
BRECHT A, 1992, ANALUSIS, V20, P135
[9]  
CREECH HJ, 1941, J AM CHEM SOC, V63, P576
[10]  
EDDOWES MJ, 1987, BIOSENSORS, V3, P1