Methylene green voltammetry in aqueous solution: Studies using thermal, microwave, laser, or ultrasonic activation at platinum electrodes

被引:43
作者
Akkermans, RP [1 ]
Roberts, SL [1 ]
Marken, F [1 ]
Coles, BA [1 ]
Wilkins, SJ [1 ]
Cooper, JA [1 ]
Woodhouse, KE [1 ]
Compton, RG [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
D O I
10.1021/jp992164b
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The voltammetry of the aqueous two-electron reduction of the phenothiazine dye methylene green, known to be passivating at platinum electrodes, is reported under simultaneous activation with each of the following techniques: thermal activation in the temperature range 15-80 degrees C, pulsed microwave activation with a modified 800 W, 2.45 GHz domestic microwave oven, 10 Hz pulsed laser activation with a Nd:YAG laser at 532 nm, sonication, or ultrasonic activation where a 20 kHz ultrasonic horn probe is employed to generate an aqueous/organic solvent emulsion. The relative merits of the five methodologies are compared and discussed in terms of surface activation and cleaning, mass-transport enhancement, and reduction mechanism elucidation. Comparisons are also drawn with the voltammetry of methylene blue, a dye of the same family. This is the first full report of both the effects of microwave heating on surface redox electrochemistry and of the sonoemulsion technique.
引用
收藏
页码:9987 / 9995
页数:9
相关论文
共 53 条
  • [1] Ultrasonic effects on electroorganic processes. Cavitation threshold values of ultrasound-oscillating power
    Atobe, M
    Nonaka, T
    [J]. CHEMISTRY LETTERS, 1997, (04) : 323 - 324
  • [2] Brett AMO, 1997, ULTRASON SONOCHEM, V4, P123
  • [3] ELECTRON-TRANSFER KINETICS AT MODIFIED CARBON ELECTRODE SURFACES - THE ROLE OF SPECIFIC SURFACE SITES
    CHEN, PH
    FRYLING, MA
    MCCREERY, RL
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (18) : 3115 - 3122
  • [4] Control of electron transfer kinetics at glassy carbon electrodes by specific surface modification
    Chen, PH
    McCreery, RL
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (22) : 3958 - 3965
  • [5] ELECTROCATALYTIC OXIDATION OF REDUCED NICOTINAMIDE COENZYMES AT METHYLENE GREEN-MODIFIED ELECTRODES AND FABRICATION OF AMPEROMETRIC ALCOHOL BIOSENSORS
    CHI, QJ
    DONG, SJ
    [J]. ANALYTICA CHIMICA ACTA, 1994, 285 (1-2) : 125 - 133
  • [6] Self-assembly of methylene blue at single-crystal platinum electrodes modified by sulphur adlayer
    Clavilier, J
    Svetlicic, V
    Zutic, V
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 402 (1-2): : 129 - 135
  • [7] Ohmic distortion of mass transport and of current-voltage curves at a channel electrode
    Coles, BA
    Compton, RG
    Larsen, JP
    Spackman, RA
    [J]. ELECTROANALYSIS, 1996, 8 (10) : 913 - 917
  • [8] Sonoelectrochemical processes: A review
    Compton, RG
    Eklund, JC
    Marken, F
    [J]. ELECTROANALYSIS, 1997, 9 (07) : 509 - 522
  • [9] VOLTAMMETRY IN THE PRESENCE OF ULTRASOUND - SONOVOLTAMMETRY AND SURFACE EFFECTS
    COMPTON, RG
    EKLUND, JC
    PAGE, SD
    SANDERS, GHW
    BOOTH, J
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (47) : 12410 - 12414
  • [10] COMPTON RG, 1995, PROG REACT KINET MEC, V20, P245