A sequential injection on-line column preconcentration system for determination of cadmium by electrothermal atomic absorption spectrometry

被引:41
作者
Xu, ZR [1 ]
Pan, HY [1 ]
Xu, SK [1 ]
Fang, ZL [1 ]
机构
[1] Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110006, Peoples R China
基金
中国国家自然科学基金;
关键词
sequential injection; electrothermal atomic absorption spectrometry; preconcentration; sorption extraction; Cd; seawater;
D O I
10.1016/S0584-8547(99)00180-9
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A sequential injection system for on-line sorbent extraction preconcentration in electrothermal atomic absorption spectrometry was developed for the determination of trace cadmium in seawater and other water samples. The system is characterized by simple manifold design and improved robustness. The Cd-APDC complex was sorbed on a 15-mu l micro-column (located at the tip of the furnace sampling probe) packed with C-18. After sequentially metering segments of ethanol, washing acid, sample and APDC complexing reagent into a 2.5-m-long, 1-mm-i.d. holding coil, the flow was reversed and directed to the column. The complexing reaction, sample loading and column washing were then achieved within the single reversed syringe stroke. The sorbed analyte was then eluted into the furnace with 50 mu l ethanol. Mutual mixing between sample, washing acid, and eluent were prevented by separating the zones with small air segments during metering. Progressive tightening of the column was avoided by a short back-suction through the column after each operational cycle. With 1 ml sample loaded, and 50 mu l eluate introduced into the furnace, an enrichment factor of 19 was obtained with a detection limit of 0.5 ng l(-1) Cd (3 sigma), a precision of 2.1% R.S.D. (n = 11), and a throughput of 12 h(-1). Good recoveries were obtained for spiked water samples and good agreement of results with standard reference seawater and river water samples were achieved. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 10 条
[1]   Determination of cadmium in seawater using automated on-line preconcentration and direct injection graphite furnace atomic absorption spectrometry [J].
Colbert, D ;
Johnson, KS ;
Coale, KH .
ANALYTICA CHIMICA ACTA, 1998, 377 (2-3) :255-262
[2]   FLOW-INJECTION ONLINE SORBENT EXTRACTION PRECONCENTRATION FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, Z ;
SPERLING, M ;
WELZ, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (07) :639-646
[3]   Trends and potentials in flow injection on-line separation and preconcentration techniques for electrothermal atomic absorption spectrometry [J].
Fang, ZL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (10) :1371-1379
[4]  
FANG ZL, 1995, FLOW INJECTION ATOMI, P148
[5]   A low consumption air-segmented sequential injection vapor generation system for the determination of mercury by atomic absorption spectrometry [J].
Ma, HB ;
Fang, ZL ;
Wu, JF ;
Liu, SS .
TALANTA, 1999, 49 (01) :125-133
[6]   DETERMINATION OF ULTRA-TRACE LEVELS OF METAL-IONS IN SEA-WATER WITH ONLINE PRECONCENTRATION AND ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
PORTA, V ;
ABOLLINO, O ;
MENTASTI, E ;
SARZANINI, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) :119-122
[7]   Preconcentration and atomic absorption determination of iron by sequential injection analysis [J].
Rubi, E ;
Jimenez, MS ;
deMirabo, FB ;
Forteza, R ;
Cerda, V .
TALANTA, 1997, 44 (04) :553-562
[8]  
Rubi E, 1996, LAB ROBOTICS AUTOMAT, V8, P149, DOI 10.1002/(SICI)1098-2728(1996)8:3<149::AID-LRA2>3.0.CO
[9]  
2-0
[10]   SEQUENTIAL INJECTION - A NEW CONCEPT FOR CHEMICAL SENSORS, PROCESS ANALYSIS AND LABORATORY ASSAYS [J].
RUZICKA, J ;
MARSHALL, GD .
ANALYTICA CHIMICA ACTA, 1990, 237 (02) :329-343