Strategies for the analysis of coal by laser ablation inductively coupled plasma mass spectroscopy

被引:24
作者
Kleiber, L [1 ]
Fink, H [1 ]
Niessner, R [1 ]
Panne, U [1 ]
机构
[1] Tech Univ Munich, Inst Hydrochem, D-81377 Munich, Germany
关键词
laser ablation; ICP-MS; coal; normalization;
D O I
10.1007/s00216-002-1433-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The potential of laser ablation inductively coupled mass spectrometry (LA-ICP-MS) was investigated for the inorganic characterization of different coal samples pressed into pellets. Reference analysis was performed by microwave-assisted digestion of the ground samples followed by ICP-MS analysis of the resulting solutions. Two different laser ablation sampling procedures were compared. For continuous sampling, three sites of the pellet were sampled for approximately one minute, whereas for sequential sampling 15 sites were sampled for two seconds, respectively. The qualitative results of the two procedures were equivalent, but continuous sampling allowed faster analysis and better precision (RSD about 10%) than sequential sampling (RSD 10-20%). Different normalization procedures with internal and extrinsic standards were investigated and allowed a quantitative determination of Al, Ti, Zn, Ni, and V with measurement uncertainties below 10% and Fe, Si, and Sn with measurement uncertainties below 20%.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 21 条
[1]  
[Anonymous], 1983, INTERPRETATION ANAL
[2]   Simultaneous elemental analysis system using laser induced breakdown spectroscopy [J].
Body, D ;
Chadwick, BL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (03) :1625-1629
[3]   The determination of low level trace elements in coals by laser ablation-inductively coupled plasma-mass spectrometry [J].
Booth, CA ;
Spears, DA ;
Krause, P ;
Cox, AG .
FUEL, 1999, 78 (14) :1665-1670
[4]   An assessment of calibration strategies for the quantitative and semi-quantitative analysis of calcium carbonate matrices by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) [J].
Craig, CA ;
Jarvis, KE ;
Clarke, LJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (08) :1001-1008
[5]  
Efron B., 1993, INTRO BOOTSTRAP, V1st ed., DOI DOI 10.1201/9780429246593
[6]   Optimised method of coal digestion for trace metal determination by atomic absorption spectroscopy [J].
Ikävalko, E ;
Laitinen, T ;
Revitzer, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (03) :314-316
[7]   Use of internal standardization to compensate for a wide range of absorbance in the analysis of glasses by UV laser ablation inductively coupled plasma atomic emission spectrometry [J].
Kanicky, V ;
Otruba, V ;
Mermet, JM .
APPLIED SPECTROSCOPY, 1998, 52 (05) :638-642
[8]   Determination of 17 trace elements in coal and ash reference materials by ICP-MS applied to milligram sample sizes [J].
Lachas, H ;
Richaud, R ;
Jarvis, KE ;
Herod, AA ;
Dugwell, DR ;
Kandiyoti, R .
ANALYST, 1999, 124 (02) :177-184
[9]  
Lewi P. J., 1997, HDB CHEMOMETRICS Q B
[10]  
Longerich HP, 1996, FRESEN J ANAL CHEM, V355, P538