Local mechanics of the lung tissue determined by functional EIT

被引:50
作者
Hahn, G
Frerichs, I
Kleyer, M
Hellige, G
机构
关键词
D O I
10.1088/0967-3334/17/4A/020
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new functional EIT (f-EIT) evaluation technique providing information on the local dynamic behaviour of the lungs is presented. Out of a series of single EIT thoracic images local time courses of the impedance change are extracted. To detect regional differences in the dynamic behaviour of the lung tissue the local time courses at different locations are related to the average time course of the impedance change over the whole thoracic cross section. The time shifts between this reference signal and the signals from separate positions are calculated from the phase information of the complex cross spectra and evaluated in terms of the local phase angle. The computed phaseshifts are imaged over the cross section creating an 'f-EIT phase image' characterizing the local dynamic properties. To relate the observed differences to the proper lung location the resulting images are presented as a combination of the f-EIT ventilation images, which represent the]local amplitude of ventilation and the f-EIT phase images. The new imaging technique was tested in spontaneously breathing humans. Alterations to pulmonary dynamics were induced by changing the body posture of the subjects. The f-EIT phase imaging procedure was shown to identify lung regions with different dynamics and it is expected that this technique will also distinguish pathologically determined alterations.
引用
收藏
页码:A159 / A166
页数:8
相关论文
共 11 条
[1]   GRAVITY-DEPENDENT SEQUENTIAL EMPTYING OF LUNG REGIONS [J].
ANTHONISEN, NR ;
ROBERTSON, PC ;
ROSS, WRD .
JOURNAL OF APPLIED PHYSIOLOGY, 1970, 28 (05) :589-+
[2]   APPLIED POTENTIAL TOMOGRAPHY [J].
BARBER, DC ;
BROWN, BH .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (09) :723-733
[3]  
Brown B H, 1987, Clin Phys Physiol Meas, V8 Suppl A, P91, DOI 10.1088/0143-0815/8/4A/012
[4]   APPLIED POTENTIAL TOMOGRAPHY - POSSIBLE CLINICAL-APPLICATIONS [J].
BROWN, BH ;
BARBER, DC ;
SEAGAR, AD .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1985, 6 (02) :109-121
[5]   EFFECT OF GRAVITY ON DISTRIBUTION OF PULMONARY VENTILATION [J].
BRYAN, AC ;
MILICEMI.J ;
PENGELLY, D .
JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (03) :778-&
[6]   ANALYSES OF SEQUENTIAL FILLING AND EMPTYING OF THE LUNG [J].
ENGEL, LA ;
PAIVA, M .
RESPIRATION PHYSIOLOGY, 1981, 45 (03) :309-321
[7]   CHANGES IN THE THORACIC IMPEDANCE DISTRIBUTION UNDER DIFFERENT VENTILATORY CONDITIONS [J].
HAHN, G ;
SIPINKOVA, I ;
BAISCH, F ;
HELLIGE, G .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 :A161-A173
[8]  
HAHN G, 1994, BIOMED TECHNIK SB, V39, P199
[9]  
HOLDER DS, 1993, CLINICAL AND PHYSIOLOGICAL APPLICATIONS OF ELECTRICAL IMPEDANCE TOMOGRAPHY, P277
[10]  
RANDALL AB, 1987, FREQUENCY ANAL, P227