Radiotherapy review on National Surgical Adjuvant Breast and Bowel Project (NSABP) phase III breast cancer clinical trials - Is there a need for submission of portal/simulation films?

被引:5
作者
Deutsch, M [1 ]
Bryant, J [1 ]
Bass, G [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, Dept Radiat Oncol, NSABP Biostat Ctr, Pittsburgh, PA 15213 USA
来源
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS | 1999年 / 22卷 / 06期
关键词
breast cancer trials; quality assurance; modality review; radiotherapy review; portal films; simulation films;
D O I
10.1097/00000421-199912000-00012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In all National Surgical Adjuvant Breast and Bowel Project (NSABP) breast cancer trials in which patients are treated with lumpectomy and postoperative breast irradiation, the quality assurance requirements dictate submission of a completed radiotherapy data form with the stated administered doses, the volumes treated, treatment prescription and daily treatment record sheets, dosimetry and calculation sheets, isodose distributions on the breast contour, photos of the patient in the treatment position, and portal or simulation films. A review of radiotherapy data on 1,982 patients who had lumpectomies accrued to seven recent NSABP breast cancer studies revealed only 2 patients who were judged to have inadequate fields. In both cases, a very small portion of the breast tissue was not included in the irradiated volume as demonstrated by the submitted films. On this basis, it was argued that submission of portal or simulation films for patients receiving postlumpectomy breast irradiation is not necessary. However, there was concern as to the incidence of patients with a possible excess amount of lung tissue included in the irradiated volume. To address this concern, the amount of irradiated lung was determined for the first 208 patients who had lumpectomies, with submitted data entered into the recent NSABP pathologic node-positive protocol B-28. Current NSABP radiation therapy guidelines suggest limiting the thickness of the irradiated lung in the portal beams to less than or equal to 3 cm. Only two patients (<1%) were found to have >3 cm of irradiated lung tissue in the treatment volume. Portal film submission is a considerable inconvenience to the individual institutions and is costly in terms of shipping, handling, and storage. These results indicate that submission of portal films is not a necessary part of quality assurance in NSABP breast cancer protocols. The NSABP has therefore eliminated the requirement for routine submission of portal films in protocols for which radiotherapy is not part of the rest question.
引用
收藏
页码:606 / 608
页数:3
相关论文
共 1 条
[1]   5-YEAR RESULTS OF A RANDOMIZED CLINICAL-TRIAL COMPARING TOTAL MASTECTOMY AND SEGMENTAL MASTECTOMY WITH OR WITHOUT RADIATION IN THE TREATMENT OF BREAST-CANCER [J].
FISHER, B ;
BAUER, M ;
MARGOLESE, R ;
POISSON, R ;
PILCH, Y ;
REDMOND, C ;
FISHER, E ;
WOLMARK, N ;
DEUTSCH, M ;
MONTAGUE, E ;
SAFFER, E ;
WICKERHAM, L ;
LERNER, H ;
GLASS, A ;
SHIBATA, H ;
DECKERS, P ;
KETCHAM, A ;
OISHI, R ;
RUSSELL, I .
NEW ENGLAND JOURNAL OF MEDICINE, 1985, 312 (11) :665-673