Partial CO2 rebreathing cardiac output -: Operating principles of the NICO™ system

被引:78
作者
Jaffe, MB [1 ]
机构
[1] Novametrix Med Syst Inc, Wallingford, CT 06492 USA
关键词
cardiac output; pulmonary capillary blood flow; Fick equation; partial rebreathing; carbon dioxide elimination; non-invasive;
D O I
10.1023/A:1009981313076
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The partial rebreathing method of cardiac output estimation is reviewed with a particular focus on its application for continuous monitoring, rebreathing and implementations and from both a historical and technical perspective. The assumptions of the method are discussed as well as the various implementations. The NICO monitor and rebreathing valve are described from a functional view. The clinical data including (a) comparisons between bolus thermodilution and continuous thermodilution in patients in the OR setting, (b) comparisons to continuous thermodilution with both the Baxter and Abbott continuous cardiac output devices and (c) comparison between different means of shunt correction are presented. Compared to conventional cardiac output methods, the partial CO2 rebreathing technique is non-invasive, can easily be automated and can provide real-time and continuous cardiac output monitoring. Taking advantage of modern sophisticated sensor and signal processing technology and integrating multiple monitored physiological variables the NICO monitor is the first commercially available cardiac output system making use of the partial rebreathing of CO2.
引用
收藏
页码:387 / 401
页数:15
相关论文
共 39 条
[1]   Partial CO2 rebreathing Fick technique for noninvasive measurement of cardiac output [J].
Bailey, PL ;
Haryadi, DG ;
Orr, JA ;
Westenskow, DR .
ANESTHESIA AND ANALGESIA, 1998, 86 (04) :SCA53-SCA53
[2]  
BLOMQVIST H, 1986, INTENS CARE MED, V12, P172
[3]   NONINVASIVE PULMONARY BLOOD-FLOW MEASUREMENT BY MEANS OF CO2 ANALYSIS OF EXPIRATORY GASES [J].
BOSMAN, RJ ;
STOUTENBEEK, CP ;
ZANDSTRA, DF .
INTENSIVE CARE MEDICINE, 1991, 17 (02) :98-102
[4]   NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT USING PARTIAL CO2 REBREATHING [J].
CAPEK, JM ;
ROY, RJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (09) :653-661
[5]  
CAPEK JM, 1998, THESIS RENSSELAER PO
[6]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[7]   White blood cell counts and plasma C3a have synergistic predictive value in patients at risk for acute respiratory distress syndrome [J].
de Abreu, MG ;
Kirschfink, M ;
Quintel, M ;
Albrecht, DM .
CRITICAL CARE MEDICINE, 1998, 26 (06) :1040-1048
[8]   Partial carbon dioxide rebreathing: A reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow [J].
deAbreu, MG ;
Quintel, M ;
Ragaller, M ;
Albrecht, DM .
CRITICAL CARE MEDICINE, 1997, 25 (04) :675-683
[9]  
DEABREU MG, 1995, P RC IEEE EMBS
[10]  
DEABREU MG, 1996, THESIS TU DRESDEN DR