A disposable electrochemical immunosensor for flow injection immunoassay of carcinoembryonic antigen

被引:165
作者
Wu, Jie
Tang, Jinhai
Dai, Zong
Yan, Feng
Ju, Huangxian [1 ]
El Murr, Nabil
机构
[1] Nanjing Univ, Key Lab Analyt Chem Life Sci, Educ Minist China, Dept Chem, Nanjing 210093, Peoples R China
[2] Jiangsu Inst Canc Prevent & Cure, Nanjing 210009, Peoples R China
[3] Univ Nantes, Fac Sci & Tech, UMR 6006, CNRS, F-44322 Nantes 3, France
基金
中国国家自然科学基金;
关键词
flow injection analysis; biosensors; immunoassay; disposable immunosensor; caicinoembryonic antigen; chitosan; screen-printed electrode;
D O I
10.1016/j.bios.2005.12.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new simple immunoassay method for carcinoembryonic antigen (CEA) detection using a disposable immunosensor coupled with a flow injection system was developed. The immunosensor. was prepared by coating CEA/colloid Au/chitosan membrane at a screen-printed carbon electrode (SPCE). Using a competitive immunoassay format, the immunosensor inserted in the flow system with an injection of sample and horseradish peroxidase (HRP)-labeled CEA antibody was used to trap the labeled antibody at room temperature for 35 min. The current response obtained from the labeled HRP to thionine-H,02 system decreased proportionally to the CEA concentration in the range of 0.50-25 ng/ml with a correlation coefficient of 0.9981 and a detection limit of 0.22 ng/ml (S/N = 3). The immunoassay system could automatically control the incubation, washing and current measurement steps with good stability and acceptable accuracy. Thus, the proposed method proved its potential use in clinical immunoassay of CEA. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:102 / 108
页数:7
相关论文
共 47 条
[1]  
ALUMANDA MDR, 1995, ANAL CHIM ACTA, V312, P85
[2]  
Alvarez MJB, 2002, ANAL CHIM ACTA, V462, P31
[3]  
[Anonymous], 1997, LUNG CANC
[4]   Aflatoxin M1 determination in raw milk using a flow-injection immunoassay system [J].
Badea, M ;
Micheli, L ;
Messia, MC ;
Candigliota, T ;
Marconi, E ;
Mottram, T ;
Velasco-Garcia, M ;
Moscone, D ;
Palleschi, G .
ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) :141-148
[5]   Novel type of flow injection immunoassay for the determination of phenytoin in serum [J].
Bereczki, A ;
Horváth, V .
ANALYTICA CHIMICA ACTA, 1999, 391 (01) :9-17
[6]  
Bremer K., 1995, EUR J CANCER, V31, pS262
[7]   Novel amperometric immunosensor for rapid separation-free immunoassay of carcinoembryonic antigen [J].
Dai, Z ;
Yan, F ;
Hua, Y ;
Hu, XY ;
Ju, HX .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 287 (1-2) :13-20
[8]   Disposable amperometric immunosensor system for rabbit IgG using a conducting polymer modified screen-printed electrode [J].
Darain, F ;
Park, SU ;
Shim, YB .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :773-780
[9]   Clinical utility of biochemical markers in colorectal cancer: European Group on Tumour Markers (EGTM) guidelines [J].
Duffy, MJ ;
van Dalen, A ;
Haglund, C ;
Hansson, L ;
Klapdor, R ;
Lamerz, R ;
Nilsson, O ;
Sturgeon, C ;
Topolcan, O .
EUROPEAN JOURNAL OF CANCER, 2003, 39 (06) :718-727
[10]   Serum CA 125, carcinoembryonic antigen, and CA 19-9 as tumor markers in borderline ovarian tumors [J].
Engelen, MJA ;
de Bruijn, HWA ;
Hollema, H ;
ten Koor, KA ;
Willemse, PHB ;
Aalders, JG ;
van der Zee, AGJ .
GYNECOLOGIC ONCOLOGY, 2000, 78 (01) :16-20